Installation Manual

26 27
Troubleshooting
Note! Turn o the syem before servicing or inspecting
Vacation Mode
When you plan to not use your RO Syem for 2 weeks or more it should be Turned O. Locate the red
Feed Water Adapter Valve connected to your Cold Water Supply (refer to page 13).
Turn O Syem: Turn the red Feed Water Adapter Valve to point away from the Red Tubing connection
(in the Closed position, page 13) to close the water supply to the syem. Unplug the power cord from
the power outlet.
Turn On Syem: Turn the red Feed Water Adapter Valve to point towards the Red Tubing connection
(in the Open position, page 13) to open the water supply to the syem. Plug the power cord back into
the power outlet.
1. Before you begin you will need a new Sediment Filter, GAC Filter, Carbon Block Filter, RO Membrane, Inline
Po Carbon Filter, and the Filter Housing Wrench. We also sugge using a bucket or bin large enough for the
syem to sit in (the syem will release a lot of water when it is disassembled).
2. Close any incoming water (Feed Water Adapter Valve page 13).
3. Open the RO Faucet handle and drain the syem completely (wait until water ow ops completely), then
close the Faucet handle.
4. Use the Filter Housing Wrench to open the Filter Housings, then remove and dispose of ONLY the
following lter cartridges:
Sediment Filter
GAC Filter
Carbon Block Filter
RO Membrane
NOTE! Leave the Inline Po Carbon Filter and Alkaline Filter in place! You will replace it after sani-
tizing the syem.
5. Mix 1 gallon of water with 2 tbsp of household bleach. Do not add bleach directly to the lter housing.
6. Fill up the Pre Filter Housings (Sediment, GAC, and Carbon Block Housings) with your mixed solution and
close the housings using your Filter Housing Wrench.
7. Open the incoming water to the syem (Feed Water Adapter Valve page 13) and let it run for 10 minutes.
8. Open the RO Faucet handle and let it drain for 10 minutes.
9. Close the RO Faucet handle and wait for 10 minutes then open the Faucet handle again and wait for it to
drain completely. (If you smell bleach from your RO Faucet repeat eps 7-9)
10. You are now ready to replace all lters and reart your syem. Please refer to page 24 and 25 for
detailed inructions, ignore any additional sanitation eps therein.
How to Sanitize your RO Syem
(Recommended Once a Year)