Installation Guide

19
Housing Assembly
Prepare Prelters
Leave the lters wrapped until you need them. When in󰍰alling
be careful not to touch the lter portion with your hands.
Remove the pla󰍰ic wrap from the 3 Filter Housings and 󰍰and
them upright. Make sure each Housing has two O-Rings rmly
in place at the top of the Housing and in the Housing’s lower
groove.
NOTE!
Reference image to place
each of the prelters in the
correct order:
- the yellow Sediment Filter
will be on the far right (under
the label “TO FEED”).
- the blue Carbon Block Filter
will be on the opposite side,
the far left.
- the green GAC Filter will be
in the center, between the
other two. The white washer
will be facing up for correct
placement.
Top Part of the Unit
Filter
Housing O-Rings
Filter Housing
3rd 2nd 1󰎣
1. The RO Membrane is already on the sy󰍰em. To
make sure the cap is secure, tighten the RO Membrane
Housing Cap clockwise by Wrench or hand.
2. Use your hands to screw each Filter Housing onto
the RO Sy󰍰em. Finish tightening each housing using
the lter wrench. DO NOT OVERTIGHTEN!
Attention
1
2