Installation Guide

27
Troubleshooting
Note! Turn o the sy󰎣em before servicing or inspecting
Vacation Mode
When you plan to not use your RO Sy󰍰em for 2 weeks to 1 month it should be Turned O. Locate the red
Feed Water Adapter Valve connected to your Cold Water Supply (refer to page 13).
Turn O Sy󰎤em: Turn the red Feed Water Adapter Valve to point away from the Red Tubing connection
(in the Closed position, page 13) to close the water supply to the sy󰍰em.
Turn On Sy󰎤em: Turn the red Feed Water Adapter Valve to point towards the Red Tubing connection
(in the Open position, page 13) to open the water supply to the sy󰍰em.
For deactivation of 1 month or more:
1. Shut o the incoming water supply and drain entire sy󰍰em of water through the RO faucet.
2. Remove each lter and place vertically on a clean surface until dry.
3. Place each lter individually in a sealed air tight pla󰍰ic wrap and place in the refrigerator for the duration
(if lter is reusable and less than 3 months old).
4. You may leave the Sy󰍰em and Filter Housings disassembled to ensure it 󰍰ays dry to prevent bacteria
growth.
5. You should wash the lter housings before replacing the lters, when you are ready to re󰍰art the sy󰍰em.
NOTE! Depending on your area’s water you may not be able to reuse some or all of your lters. Please
contact us if you need more information.