After shutting o the main water line open all of your home plumbing xtures to drain as much water
as possible and reduce pressure in your plumbing.
Prepare Your Inall Site
Your inall location should be at any point after the main water supply line enters your home, but
before the line splits or meets the hot water heater. If your line branches o to outdoor and indoor
plumbing you may wish to inall on the indoor line if you would only like to lter your indoor water.
Measure the amount of line you will need to remove at your inall location.
You will need enough space for the syem, and any adapters, shut-o valves, bypass valves, or other
ttings you may need.
Prepare for the line to discharge water once cut. Allow the line to drain before proceeding. Make sure
the end of the line is smooth with no jagged edges after cutting.
You can mount the syem to the wall at your inall location, or it can and on its frame on the oor.
If you are mounting the syem o the oor make sure the wall can support the weight of the syem
when full of water.
Attach Plumbing
Attach the necessary pipes, valves, and ttings to each side of the syem.
Once all of your pipes and connections are complete and ow is opened you are ready to turn your
water back on.
Reart Water Flow
Turn your main water valve back on slowly. You will be able to hear the sound of water entering the
Whole House Filtration Syem, after a while the syem will be full and sound will op. Now, you will
need to ush the syem before you are ready to use the water.
Go to your neare water faucet and turn on a ow of COLD WATER.
DO NOT USE HOT WATER FOR THE SYSTEM FLUSH
Observe your syem and piping for any leaks.
The ush water will be blackish as loose carbon particles are ushed out of the syem. The water may
also appear cloudy as air bubbles are pushed out of the syem and your pipes after the shut down.
This is perfectly normal. Run the water until it becomes clear, then run for 5 additional minutes before
turning the faucet o.
Wait 30 minutes, then run the cold water again for 10 minutes.
Shut o your faucet.
Your syem is now ready for use!
Start-Up Notes
The cloudiness may persi for anywhere between 1 day to 1 week as your syem and pipes expel tiny
air bubbles from your plumbing and the carbon lters. This is perfectly normal and the air bubbles are
harmless. They should clear up within a week of regular use.
Occasionally check for leaks during your r week of use to be sure all of your connections are able.
You can ush the old non-ltered hot water from your plumbing by running your hot water at this
point. Or you can expend this water through regular use over the next few days.
Make sure to turn your water heater on again.
Inallation