User manual
11
Seriell RS-422/485 PCIe Board English
485-2W
485-4W
422
There are 2 sets of the jumpers to set the settings for port 1 (S1) and port 2 (S2)
respectively.
1. Mode Selection Jumper: JP4 for S1 and JP7 for S2
2. Termination Resistor Enable/Disable Jumper: JP8 for S1 and JP9 for S2
3. Echo or No Echo Selection Jumper: JP5 for S1 and JP6 for S2
4. TXD Control Selection Jumper: JP2 for S1 and JP3 for S2
485-2W = RS-485 Mode with 2-wire (Default)
485-4W = RS-485 Mode with 4-wire
422 = RS-422 Mode
1. Mode Setting:
This jumper is to set the transmission data will be echoed back or not. The Echo
mode is useful for the application program to detect if the RS485 bus has collision. If
the echoed data was not equal to the transmitted data, then the bus was in a colli-
sion. This setting only affects the RS485 2-wire mode. It doesn’t affect RS485 4-
wire, RS422, and RS232 modes.
2. Termination Resistor Enable/Disable:
This jumper enables/disables the 120 Ohm termination resistor between DATA+ and
DATA- of the RS485 transceiver:
OFF ON
OFF = Termination Resistor Disabled (Default)
ON = Termination Resistor Enabled
3. Echo or No Echo Settings:
OFF ON
OFF = No Echo Data (Default)
ON = Transmission data will be echoed
3.3 Jumper setting
JP4 for S1 Port
JP7 for S2 Port
JP8 for S1 Port
JP9 for S2 Port
JP5 for S1 Port
JP6 for S2 Port