MSDS

Golden Powe
r
Co
r
po
r
a
tion (HK) Lt
d
.
Page 1
/
3
Material
Safety Data
S
h
ee
t
IDENTITY (As Read on Label and Line)
G6F22 LONG LIFE BATTERY
Section
I
Notice: Blank spaces are not permitted. If any item is not
applicable, or no information is available, the space must
be marked to indicate that.
Manufacturers Name
Golden Power Corporation (HK) Ltd.
Telephone Number
(852) 3125 2288
Fax Number
(852) 3125 2000 / 3125 2001
Address (Number, Sheet, City, State, and ZIP Code)
Flat C, 20/F., Block 1, Tai Ping Industrial Centre,
57 Ting Kok Road, Tai Po, N.T., Hong Kong
Date Prepared
Jan
10, 2012
Signature of Preparer (optional)
Section II
Hazardous Ingredients/Identity
I
n
fo
r
m
a
t
io
n
Hazardous Components (Specific Chemical Identity, Common Names) (contents, %/wt) CAS No.
Manganese Dioxide (MnO
2
) 28.88% 1313-13-9
Acetylene Black (C
2
H
2
) 5.25 % 74-86-2
Zinc (Zn) 8.75 % 7440-66-6
Zinc Chloride (ZnCl
2
) 4.16 % 7646-85-7
Ammonium Chloride (NH
4
Cl) 8.70 % 12125-02-9
Mercury
(Hg) <0.0001 % 7439-97-6
Lead (Pb) 0.025 % 7439-92-1
Cadmium (Cd) <0.0005% 7440-43-9
Section III
Physical/Chemical
C
h
a
r
a
c
t
e
r
is
t
ics
Boiling Point
ZnCl
2
& NH
4
Cl aqua solution = 104
o
C
Specific Gravity (H
2
O=1)
Zn = 7.1, ZnCl
2
= 2.91, NH
4
Cl = 2.0
Vapor Pressure (mmHg)
ZnCl
2
aqua solution = 3mmHg at 20
o
C
NH
4
Cl aqua solution = 2mmHg at 20
o
C
Melting Point
MnO
2
decompose at 535
o
C, Zn = 420
o
C
ZnCl
2
& NH
4
Cl aqua = 2
o
C
Vapor Density (Air = 1)
Evaporation Rate
(Butyl Acetate = 1)
Solubility in Water ZnCl
2
& NH
4
Cl – complete
Appearance and Color
MnO
2
is a black powder, Acetylene Black is also a black powder, and Zinc is a silver metal.
ZnCl
2
& NH
4
Cl aqua is a colorless liquid with stimulative order.
Section IV
Fire
and Explosion
Hazard
D
a
t
a
Flash Point (Method Used)
Incombustible
Flammable Limits
Not Available
LEL UEL
Extinguishing Media: See Special Fire Fighting Procedure
Special Fire Fighting Procedure: In case of fire in an adjacent area, use water, CO
2
or dry chemical extinguishers if cells
are packed in their original containers since the fuel of the fire is basically paper products. For bulk quantities of
unpackaged cells use LITH-X (Graphite Base). In this case, do not use water.
As with any fire, wear self-contained breathing apparatus to
avoid inhalation of hazardous decomposition products.
Unusual Fire and Explosion Hazards

Summary of content (3 pages)