User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.
Introduction Congratulations on your purchase of Extech’s Model 45170 4-in-1 Humidity, Temperature, Airflow and Light Meter. With careful use, this meter will provide years of reliable service. Meter Description 1. Vane Airflow Sensor 2. Type K Thermocouple Input Jack 3. Display 4. Power Button 5. Unit /Zero Button 6. C°/F° /Lux/Ft-cd Button 7. Light Sensor 1 8 2 8. 9. 3 9 4 RH and Air Temperature Sensors 5 Hold Button 10 11 6 10. Max/Min Button 7 11. Function Button 2 45170 V1.
Operation Turn Power ON Press the power button to turn power on. The meter will perform a short self-test. A. Air Velocity Measurements 1. Press the Function button to select the Anemometer mode. In Air Flow mode, the display will show Air Velocity and Temperature. 2. Press Unit/Zero button to select desired unit of measure (FPM, MPH, KNOT, KM/H, or M/S) and face the Air Flow Sensor towards the source of wind. 3. Allow time for the reading to stabilize and note value.
Data Hold Press the HOLD button to freeze the reading in the display. The 'HOLD' icon will appear on the upper right-hand side of the display. Press the HOLD button again to return to normal operation (the 'HOLD' hold icon will disappear). Auto Power OFF The meter will automatically turn off after 10 minutes if no keys are pressed during this period. Auto power off is disabled in the max/min recording mode. Turning Power OFF Press the power button to turn power off.
Specifications Range Specifications Measurement Range Resolution Accuracy MPH (Miles per hour) 0.9 to 67.0MPH 0.1MPH km/hr (kilometers per hour) 1.4 to 108.0 km/h 0.1km/h ≤ 3937 ft/min: ±3% F.S. Knots (nautical miles per hour) 0.8 to 58.3 knots 0.1knots > 3937 ft/min: ±4% F.S m/sec (meters per second) 0.4 to 30.0 m/s 0.1 m/s ft/min (feet per minute) 80 to 5910 ft/min Temperature/Thermistor 32 to 122 F (-0 to 50 C) Temperature /Thermocouple Relative Humidity 1ft/min 0.1oF/C ± 2.