INSTRUCTIONS
MODEL ET25 - Voltage Tester
3-wire AC Grounded Outlets: Insert probes into the hot (narrow) and neutral (wide)
slots of the receptacle. Tester will glow on a live circuit. To check grounding, insert one
probe into the hot (narrow) side and the other into the “U” shaped ground. Tester
should glow.
2-wire AC Outlets: Insert probes into both slots of the receptacle. Tester will glow on a
live circuit. To determine hot wire, insert one probe into one of the slots and touch the
other probe to the metal mounting screw or metal plate. If the screw is grounded, the
tester will glow when connected to the hot wire.
3-wire 220V AC Outlets: Test for normal (110V) glow between round slot (neutral) and
either hot side. Test will glow brighter when placed across both hot sides (220V).
Specifications
Voltage Range: 80~250VAC/DC (50/60Hz)
Indoor use only; 7000 ft. (2000m) Altitude (maximum)
Operating Temperature: 23 ~ 104
o
F (-5 ~ 40
o
C)
Maximum Relative Humidity: 85% for temperature up to 88
o
F (31
o
C) decreasing linearly to 50% at 104
o
F
(40
o
C)
Transient overvoltage according to INSTALLATION CATEGORIES (OVERVOLTAGE CATEGORIES) CAT II
300V
POLLUTION DEGREE 2; ETL LISTED
Cleaning: Wipe the surface of the test with a dry cloth
Caution: Read Manual before using the meter
Double insulation: Tester is protected throughout by double or reinforced insulation.
Warning: Maximum range of this tester is 250V; it can indicate the presence of voltage 80~250V AC/DC; do not assume that no
indication necessarily means a no-power condition. FLIR Systems, Inc. is not responsible for any injury or damages due to improper
use of this tester.