User manual

EX470-EU_ENG V2.1 8/07
13
Specifications
Function Range Resolution Accuracy
400mV 0.1mV
±(0.3% reading + 2 digits)
4V 0.001V
40V 0.01V
400V 0.1V
±(0.5% reading + 2 digits)
DC Voltage
1000V 1V
±(0.8% reading + 3 digits)
50 to 400Hz 400Hz to 1kHz
400mV 0.1mV
±(1.5% reading + 15
digits)
±(2.5% reading +
15digits)
4V 0.001V
40V 0.01V
400V 0.1V
±(1.5% reading + 6
digits)
±(2.5% reading + 8
digits)
AC Voltage
750V 1V
±(1.8% reading + 6
digits)
±(3% reading + 8 digits)
400μA 0.1μA
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.5% reading + 3 digits)
4A 0.001A
DC Current
20A 0.01A
±(2.5% reading + 5 digits)
50 to 400Hz 400Hz to 1KHz
400μA 0.1μA
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.8% reading + 8
digits)
±(3.0% reading + 7
digits)
4A 0.001A
AC Current
20A 0.01A
±(3.0% reading + 8
digits)
±(3.5% reading + 10
digits)
400Ω 0.1Ω ±(0.8% reading + 4 digits)
4kΩ 0.001kΩ ±(0.8% reading + 2 digits)
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ
±(1.0% reading + 2 digits)
Resistance
40MΩ 0.01MΩ ±(3.0% reading + 5 digits)
40nF 0.01nF
±(5.0% reading + 7 digits)
400nF 0.1nF
±(3.0% reading + 5 digits)
4μF 0.001μF
40μF 0.01μF
±(3.5% reading + 5 digits)
Capacitance
100μF 0.1μF ±(5.0% reading + 5 digits)
-20 to 750°C 1°C
Temp
(type-K)
-4 to 1382°F 1°F
±(3.0% reading + 3 digits)
(probe accuracy not included)
-50 to 270°C 1°C
Temp
(IR)
-58 to 518°F 1°F
±2.0% reading or ±2°C, ± 4 °F
NOTE: Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.