User manual

USER PARAMETERS
30
Chapter 8
Summary table
Display D1 Display D2 Function
06:00 UT B Start of day time/end of night time
22:00 UT C End of day time/start of night time
25°C UT D Day time max. temperature
20°C UT E Night time max. temperature
When the stove switches o due to the maximum temperature reached, DOFF will appear on display D1.
The stove switches back on automatically when the room temperature lowers by 3°C with respect to the
maximum temperature set.
Es. State of the stove – do
Maximum temperature set - 25°C
When the room temperature falls below 22°C (25 – 3 = 22 °C), the stove will re-start automatically.
N.B. The stove can only re-ignite from the DOFF state and not from the OFF state.
The manual controls, from the display or remote control, always remain priority with respect to
programming.
PELLET FEED ADJUSTMENT
If the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from
the control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
LACK OF FUEL:1.
the stove can never develop a suitable  ame, tending to remain very low even at high powers
at minimum power the stove tends to almost switch o taking the stove into NO PELL alarm
conditions.
when the stove displays the NO PELL alarm, there may be non-burned pellets inside the pot
EXCESS FUEL:2.
the stove develops a very high  ame even at low power
the panoramic glass is very dirty, obscuring it almost totally
the pot tends to become encrusted, blocking the holes for air intake due to the excessive pellet feed,
as it is only burned partially
N.B. If the problem occurs after only a few months working, check that routine cleaning stated in the stove
booklet, has been carried out correctly.
The regulation to be performed is a percentage. Therefore a modi cation of this parameter will lead to a
proportional variation of all stove feeding speeds.