ATTENTION SURFACES CAN BECOME VERY HOT! ALWAYS USE PROTECTIVE GLOVES! During combustion, thermal energy is released that significantly increases the heat of surfaces, doors, handles, controls, glass, exhaust pipes, and even the front of the appliance. Avoid contact with those elements if not wearing protective clothing (protective gloves included). Make sure children are aware of the danger and keep them away from the stove during operation. ENGLISH..........................................................
We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner or user, or if transferred to another place.
Do not leave the packaging elements within reach of children or unassisted disabled persons. The hearth door must always be closed during normal functioning of the product. When the appliance is functioning and hot to the touch, especially all external surfaces, attention must be paid Check for the presence of any obstructions before switching the appliance on following a prolonged period of inactivity. The generator has been designed to function in any climatic condition.
INSTALLATION General The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.
In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: they must be protected with grids, metal mesh, etc.
Pellets and feeding Pellets are made by applying high pressure to sawdust, or wood waste products (not containing paint) from sawmills, carpentry and other activities related to processing and working with wood. Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly. In fact the compactness of the pellets over time is guaranteed by a natural substance found in the wood itself: wood coal.
SOUVENIR and ILENIA - ANNABELLA spacers Models “ SOUVENIR” and "ILENIA - ANNABELLA" feature 4 spacers at the back which delimit the minimum distance to be maintained from any rear support. The spacers must not be removed. HOT AIR DUCTING The pipe used for ducting the hot air must have an internal diameter of 80 mm, be insulated and protected against heat loss.
Features: ducting outlet diameter: 80 mm maximum recommended ducting length 6m it is not possible to thermostat the ducting possibility to adjust the fan speed in percentage. Position "A" Position "C" GRAZIOSA PLUS, IRMA PLUS, Novella Plus & Sibilla Plus For GRAZIOSA PLUS, IRMA PLUS, Novella Plus & Sibilla Plus model it is mandatory to duct the hot air.
Features: ducting outlet diameter: 2x80 mm maximum recommended ducting length 2m it is not possible to thermostat the ducting possibility to adjust the fan speed in percentage additional thermostat for ducting motor control For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external thermostat will allow to control the ducting motor independently from stove functioning.
Control panel Display of various Text messages BUTTON ON/OFF TO ACCESS THE Menu 1 2 6 4 OFF 3 5 ADJUSTMENT OPERATING POWER TEMPERATURE SETTING Display icons key 1 Indicates the receipt of the radio signal On = during radio communication Off = no radio communication Fixed on = serial input disabled Indicates the status of the additional thermostat input (GND - I3) It indicates fumes motor operation.
General menu 2 1 1 2 3 6 6 1 4 4 OFF 3 5 5 Go back - exit 2 3 Parameter scrolling: next (2) ; previous (3) 4 5 Modify settings data: increase (4); decrease (5) 6 Confirm - access Menu 6 Set Clock 6 *Enable Chrono 6 2 2 Chrono Setting 6 Language 6 User 6 Enable chrono Day PROG. 1 - 2 - 3 - 4 on/off 2 2 2 Confirm With key 6 IT,EN,FR,DE,ES Pellets 2 2 Stand by Date ...Sunday prg1 2 Month on-off 2 Tangential (Reserved to the qualified technician) 2 Monday prg1...
THE REMOTE CONTROL All that can normally be implemented through the LCD can be adjusted using the remote control.
Mains frequency 50/ 60Hz In the event the stove is installed in a country with 60Hz frequency, the stove will display "frequenza rete errata" ("mains frequency incorrect"). Vary the frequency as described below. Controls procedure Press key 6, Select the frequency required using key 4 or 5. Press key 6 to confirm and key 1 to return to the previous menus up to the initial status.
Operation and logic 2 1 6 4 OFF 3 5 Ignition Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are given for the ignition stage, after ignition and once the control temperature has been reached, the stove interrupts the ignition phase and switches to the START-UP mode. Starting During the start-up stage, the stove stabilises combustion, increasing it gradually, to then start ventilation and switch to the WORK mode.
additional thermostat (optional) The appliance can control the room temperature using an additional external thermostat (optional). After ignition (pressing key 1 or via chrono mode), the stove will work to reach the setting set on the thermostat, displaying Work (contact closed). The standard room probe is automatically ignored. When the room temperature has been reached (open contact) the stove will go to minimum, displaying modulate.
No fuel: the stove can never develop a suitable flame, tending to remain very low even at high powers. at minimum power the stove tends to almost switch-off taking the stove into “no pellets” alarm condition. when the stove displays the “no pellets” alarm, there may be non-burned pellets inside the burn pot. Excess fuel: the stove develops a very high flame even at low power. the panoramic glass is very dirty, obscuring it almost totally.
If the Stby function is not active (OFF), if the stove reaches the set room temperature, it will go to minimum, modulating and displaying modulate. When the room temperature is below the setting, it will start to work again at the set power and displaying work. stand - by with additional thermostat The Stby function is used if immediate stove switch-off is required when the set temperature has been reached. By default the STBY function is always set on OFF (light on).
V2 - Air The menu allows to adjust the speed of the ducted fan in percentage. Controls procedure Press key 6 and set clock will appear. Press key 2 several times until user is displayed. Press key 6. Press key 2 until "v2 air" appears. Use keys 4 -5 to increase (4) or decrease (5) Press key 6 to confirm and key 1 to return to the previous menus up to the initial status. 2 reset Allows to reset all values modifiable by the user to the default values.
Programming example Let's suppose that the weekly Programmer function is to be used and 4 time slots are to be used in the following way: - 1st time slot: from 08:00 to 12:00 every day of the week, with room temperature at 19°C, excluding Saturday and Sunday - 2nd time slot: from 15:00 to 22:00 only on Saturday and Sunday, with room temperature at 21°C Controls procedure: Press key 6 and SET clock will appear. Press key 2 until enable chrono appears Enable the chrono Enable slot 1 and 2.
Cleaning And Maintenance Always follow the instructions in maximum safety conditions! Make sue the power cable is unplugged since the generator could be programmed to start. That the generator is cold in its entirety. The ashes are completely cold. Ensure an effective exchange of air in the room during the cleaning of the product.
Open the door - Clean the glass with a damp cloth Never spray the detergent or any other liquid used for cleaning directly on the ceramic glass Cleaning the burn pot and combustion chamber 1. Vacuum the residues in the burn pot 2. Take out the burn pot from the designated compartment; 3. Vacuum the ash from the burn pot's seat and the combustion chamber (3.1) 4. Use the special poker supplied to clear the holes in the burn pot. 5. Place back the burn pot and push it towards the hearth wall. 6.
EVERY 3/4 DAYS - WEEKLY Ash drawer Every 3-4 days check the ash drawer and empty it at least one/twice a week. If there is a lower door, open/remove it. Take out the removable ash drawer and empty it in a special container. Vacuum the area underneath the removable ash drawer. Once you have cleaned it, place back the removable drawer and close/place back the external door. In some stoves the ash collector tray is located in the combustion chamber.
A B D *C D *D E E *E F F F Cleaning the LOWER SUMP (IF THERE IS ONE) Some stove models have an inspection sump behind the ash drawer or underneath the combustion chamber. In this case, just open, remove the clamping screws and vacuum the ash inside.
ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS Routine maintenance must be performed at least once a year. As the generator uses pellets as solid fuel, it needs an annual routine maintenance interval that needs to be performed by an authorised Technician by only using original spare parts. Failure to do so can affect the appliance's safety and you may no longer be entitled to the warranty conditions.
The images are for illustration purposes. D C A C A B A A Fumes motor (disassembly and cleaning and fumes pipe), new silicone in required points B Inspection of gaskets, ash drawer and burn pot door (replace them and apply silicone where required) C Combustion chamber (total cleaning of the entire chamber) and ignition plug tube cleaning D Tank (complete emptying and cleaning).
The images are for illustration purposes. C D F A B C E E A C F B F B 28 A Fumes motor (disassembly and cleaning and fumes pipe), new silicone in required points B Inspection of gaskets, ash drawer and burn pot door (replace them and apply silicone where required) C Combustion chamber (total cleaning of the entire chamber) and ignition plug tube cleaning D Tank (complete emptying and cleaning).
Displays Display off Start Pellet feeding Reason Solution Stove off - The start-up phase is in progress - The feeding of the pellet during the ignition phase is in progress Ignition The ignition phase is in progress - BURNING The start-up phase is in progress - OPERANT The normal work phase is in progress - The stove is modulating - Modulation The automatic burn pot cleaning is in The automatic burn pot cleaning (not in 1st power) is performed at pre-established intervals of continued wo
ALARMS DISPLAY EXPLANATION SOLUTION Indicates the presence of an alarm. On: indicates the presence of an alarm Off: indicates the absence of alarms Flashing: indicates the deactivation of the depression sensor. The alarm can be reset by pressing key 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have passed from displaying the same alarm. Fault related to the flue gas exhaust motor. The restoration operations must be carried out by an authorised technician.
GUARANTEE TERMS 1. Extraflame S.p.A. products are guaranteed, within the European community, for 24 months from the date of purchase. Purchase has to be proved by means of a valid fiscal document issued by the seller (receipt, invoice or shipment document) identifying the purchased product and its purchase and/or delivery date. Warning: This conventional guarantee does not replace the guarantee regulated by the European legislation on consumer rights.
Additional warnings Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator. Do not use the product as a ladder or supporting structure. Do not place laundry on the product to dry it. Any clothes-horse or similar objects must be kept at due distance from the product. Danger of fire or damage to the coating. The user is fully liable for any incorrect use of the product. The manufacturer bears no civil or criminal liability for incorrect use.
ENGLISH 33
ENGLISH
ENGLISH 35
EXTRAFLAME S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY +39.0445.865911 - +39.0445.865912 - info@extraflame.it - www.lanordica-extraflame.com The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice, in order to improve its products. This manual cannot be considered as a contract for third parties.