Operation Manual
OFF
1
2
3
4
5
6
ENGLISH
CONTROL PANEL
BUTTON
ON/OFF
DISPLAY OF VARIOUS
TEXT MESSAGES
TO ACCESS
THE MENU
TEMPERATURE
SETTING
DISPLAY ICONS KEY
Indicates the receipt of the radio signal
On = during radio communication
O = no radio communication
Fixed on = serial input disabled
Indicates the status of the additional thermostat input (GND - I3)
It indicates fumes motor operation.
O = fumes motor disabled
On = fumes motor active
Flashing = breakdown
It indicates ducted motor operation
O = Motor disabled
On = Motor active
Flashing = the motor is running at minimum and in modulation
mode (additional input open)
1
It indicates tangential fan operation (where applicable)
O = not working
On = working
Flashing = motor at minimum
Indicates the activation of the F1 function (future set-up)
O = function disabled
On = function active
It indicates pellet feed motor operation
O = pellet feed motor disabled
On = pellet feed motor active
It indicates weekly programming functioning
Indicator on = weekly programming active
Indicator o = weekly programming disabled
Indicates the compensation function
O = the function is disabled
On = the function is active
Indicates the stove modulation
On = the stove is working at the set power
Flashing = the power at which the stove is working is dierent to
the power set, the stove is modulating (for various reasons)
Indicates the contact of the external additional thermostat
Contact closed: the contact of the external additional
thermostat is closed and the STBY
function is disabled
Contact open: the contact of the external additional
thermostat is open and the STBY
function is disabled
Flashing with closed
contact:
the contact of the external additional
thermostat is closed and the STBY
function is active
Flashing with open
contact:
the contact of the external additional
thermostat is open and the STBY
function is active
Indicates the presence of an alarm.
On: indicates the presence of an alarm
O: indicates the absence of alarms
Indicates the room temperature status
O = the T° read by the probe is above the set temperature
On = the T° read by the probe is below the set temperature
Tank probe
O = probe ok
On = broken probe (short circuit or open)
Flashing = modulation due to tank
ADJUSTMENT
OPERATING POWER