Reference Guide

Table Of Contents
Column Meaning
Dynamic Address count Number of MAC addresses in the forwarding database that were
automatically learned.
Static Address (User-defined) count Number of MAC addresses in the forwarding database that were manually
entered by a user.
Total MAC Addresses in use Number of MAC addresses currently in the forwarding database.
Total MAC Addresses available Number of MAC addresses the forwarding database can handle.
process cpu threshold
Use this command to configure the CPU utilization thresholds. The Rising and Falling thresholds are
specified as a percentage of CPU resources. The utilization monitoring time period can be configured
from 5 seconds to 86400 seconds in multiples of 5 seconds. The CPU utilization threshold configuration
is saved across a switch reboot. Configuring the falling utilization threshold is optional. If the falling CPU
utilization parameters are not configured, then they take the same value as the rising CPU utilization
parameters.
Format process cpu threshold type total rising rising-threshold
interval rising-interval [falling falling-threshold interval
falling-interval]
Mode Global Config
Parameter Description
rising-threshold
The percentage of CPU resources that, when exceeded for the configured rising
interval, triggers a notification. The range is 1 to 100. The default is 0 (disabled).
rising-interval
The duration of the CPU rising threshold violation, in seconds, that must be met to
trigger a notification. The value must be a multiple of 5, and the range is 5 to 86400.
The default is 0 (disabled).
falling-threshold
The percentage of CPU resources that, when usage falls below this level for the
configured interval, triggers a notification. The range is 1 to 100. The default is 0
(disabled).
A notification is triggered when the total CPU utilization falls below this level for a
configured period of time. The falling utilization threshold notification is made only
if a rising threshold notification was previously done. The falling utilization threshold
must always be equal or less than the rising threshold value. The CLI does not allow
setting the falling threshold to be greater than the rising threshold.
falling-interval
The duration of the CPU falling threshold, in seconds, that must be met to trigger a
notification. The value must be a multiple of 5, and the range is 5 to 86400. The
default is 0 (disabled).
show process app-list
This command displays the user and system applications.
Note
This command is available in Linux 2.6 only.
Utility Commands
ExtremeSwitching 200 Series: Command Reference Guide for version 01 .02.04.0007 156