Reference Guide

Table Of Contents
Format show poe port info { all | unit/slot/port }
Mode Privileged EXEC
(Extreme 220) #show poe port info all
High Max Output Output
Intf Power Power Class Power Current Voltage Status Fault
(mW) (mW) (mA) (V) Status
------ ------- -------- -------- ------- ------- ------- -----------------
-----------------
2/0/1 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/2 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/3 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/4 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/5 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/6 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/7 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/8 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/9 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/10 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/11 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/12 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/13 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/14 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/15 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/16 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/17 Yes 32000 Unknown 0 0 0 Disabled No Error
2/0/18 Yes 32000 Unknown 0 0 0 Disabled No Error
Simple Network Time Protocol Commands
This section describes the commands used to automatically configure the system time and date by
using SNTP.
sntp broadcast client poll-interval
This command sets the poll interval for SNTP broadcast clients in seconds as a power of two where poll-
interval can be a value from 6 to 10.
Default
6
Format sntp broadcast client poll-interval poll-interval
Mode Global Config
no sntp broadcast client poll-interval
This command resets the poll interval for SNTP broadcast client back to the default value.
Format
no sntp broadcast client poll-interval
Mode Global Config
Utility Commands