Reference Guide

Table Of Contents
logging persistent
Use this command to configure the persistent logging for the switch.
Possible severity levels for logging messages are as follows. (You can enter either the word or the
corresponding numeral.)
emergency (0): The device is unusable.
alert (1): Action must be taken immediately.
critical (2): The device is experiencing primary system failures.
error (3): The device is experiencing non-urgent failures.
warning (4): The device is experiencing conditions that could lead to system errors if no action is
taken.
notice (5): The device is experiencing normal but significant conditions.
info (6): The device is providing non-critical information.
debug (7): The device is providing debug-level information.
Default Disabled
Format logging persistent severity-level
Mode Global Config
no logging persistent
Use this command to disable the persistent logging in the switch.
Format
no logging persistent
Mode Global Config
mbuf
Use this command to configure memory buer (MBUF) threshold limits and generate notifications
when MBUF limits have been reached.
Format
mbuf {falling-threshold | rising-threshold | severity}
Mode Global Config
Field Description
rising-threshold
The percentage of the memory buer resources that, when exceeded for the
configured rising interval, triggers a notification. The range is 1 to 100. The default is
0 (disabled).
falling-threshold
The percentage of memory buer resources that, when usage falls below this level
for the configured interval, triggers a notification. The range is 1 to 100. The default
is 0 (disabled).
severity
The severity level at which Mbuf logs messages. The range is 1 to 7. The default is 5
(L7_LOG_SEVERITY_NOTICE).
Utility Commands
ExtremeSwitching 200 Series: Command Reference Guide for version 01 .02.04.0007 242