Column Meaning
Alarm Falling
Threshold
The falling threshold for the sample statistics. The range is 2147483648 to 2147483647. The
default is 1.
Alarm Falling Event
Index
The index of the eventEntry that is used when a falling threshold is crossed. The range is 1
to 65535. The default is 2.
Alarm Startup Alarm The alarm that may be sent. Possible values are rising, falling or both rising-falling. The
default is rising-falling.
Alarm Owner The owner string associated with the alarm entry. The default is monitorAlarm.
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show rmon alarms
Index OID Owner
----------------------------------------------
1 alarmInterval.1 MibBrowser
2 alarmInterval.1 MibBrowser
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show rmon alarm 1
Alarm 1
----------
OID: alarmInterval.1
Last Sample Value: 1
Interval: 1
Sample Type: absolute
Startup Alarm: rising-falling
Rising Threshold: 1
Falling Threshold: 1
Rising Event: 1
Falling Event: 2
Owner: MibBrowser
show rmon collection history
This command displays the entries in the RMON history control table.
Format
show rmon collection history [interfaces unit/slot/port]
Mode Privileged EXEC
Column Meaning
History Control Index An index that uniquely identifies an entry in the historyControl table. Each such entry
defines a set of samples at a particular interval for an interface on the device. The range
is 1 to 65535.
History Control Data
Source
The source interface for which historical data is collected.
History Control Buckets
Requested
The requested number of discrete time intervals over which data is to be saved. The
range is 1 to 65535. The default is 50.
History Control Buckets
Granted
The number of discrete sampling intervals over which data shall be saved. This object is
read-only. The default is 10.