Reference Guide

Table Of Contents
Column Meaning
History Control Interval The interval in seconds over which the data is sampled. The range is 1 to 3600. The
default is 1800.
History Control Owner The owner string associated with the history control entry. The default is
monitorHistoryControl.
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show rmon collection history
Index Interface Interval Requested Granted Owner
Samples Samples
----------------------------------------------------------------------
1 1/0/1 30 10 10 myowner
2 1/0/1 1800 50 10 monitorHistoryControl
3 1/0/2 30 50 10 monitorHistoryControl
4 1/0/2 1800 50 10 monitorHistoryControl
5 1/0/3 30 50 10 monitorHistoryControl
6 1/0/3 1800 50 10 monitorHistoryControl
7 1/0/4 30 50 10 monitorHistoryControl
8 1/0/4 1800 50 10 monitorHistoryControl
9 1/0/5 30 50 10 monitorHistoryControl
10 1/0/5 1800 50 10 monitorHistoryControl
11 1/0/6 30 50 10 monitorHistoryControl
12 1/0/6 1800 50 10 monitorHistoryControl
13 1/0/7 30 50 10 monitorHistoryControl
14 1/0/7 1800 50 10 monitorHistoryControl
15 1/0/8 30 50 10 monitorHistoryControl
16 1/0/8 1800 50 10 monitorHistoryControl
17 1/0/9 30 50 10 monitorHistoryControl
18 1/0/9 1800 50 10 monitorHistoryControl
19 1/0/10 30 50 10 monitorHistoryControl
--More-- or (q)uit
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show rmon collection history interfaces 1/0/1
Index Interface Interval Requested Granted Owner
Samples Samples
----------------------------------------------------------------------
1 1/0/1 30 10 10 myowner
2 1/0/1 1800 50 10 monitorHistoryControl
show rmon events
This command displays the entries in the RMON event table.
Format
show rmon events
Mode Privileged EXEC
Parameter Description
Event Index An index that uniquely identifies an entry in the event table. Each such entry defines
one event that is to be generated when the appropriate conditions occur. The range
is 1 to 65535.
Event Description A comment describing the event entry. The default is alarmEvent.
Utility Commands