Reference Guide

Table Of Contents
Column Meaning
Pluggable Cards are pluggable or non-pluggable in the slot.
Power Down Whether the slot can be powered down.
If you supply a value for unit/slot, the following additional information appears:
Column Meaning
Inserted Card Model
Identifier
The model identifier of the card inserted in the slot. Model Identifier is a 32-
character field used to identify a card. This field is displayed only if the slot is full.
Inserted Card Description The card description. This field is displayed only if the slot is full.
Configured Card Description 10BASE-T half duplex
show stack-status
Use this command to display the stack unit’s received HB message timings, and the dropped/lost
statistics for the specified unit.
Format show stack stack-status [1-n | all] [clear]
Mode Privileged EXEC
Column Meaning
Current Current time of heartbeat message reception
Average Average time of heartbeat messages received
Min Minimum time of heartbeat messages received
Max Maximum time of heartbeat messages received
Dropped Heartbeat message dropped/lost counter
This example dumps the stack unit heartbeat status information of the specified unit.
(Extreme 220) (Routing) #show stack-status
Stack Unit 1 Status
Sampling Mode: Cumulative Summing
--------------------------------------
Unit Current Average Min Max Dropped
--------------------------------------
show supported cardtype
This commands displays information about all card types or specific card types supported in the
system.
Format
show supported cardtype [cardindex]
Mode
User EXEC
Privileged EXEC
Stacking Commands
ExtremeSwitching 200 Series: Command Reference Guide for version 01 .02.04.0007 27