Reference Guide

Table Of Contents
Column Meaning
Port Up Time Since Counters Last
Cleared
Time since port was reset, displayed in days, hours, minutes, and seconds.
STP BPDUs Transmitted Spanning Tree Protocol Bridge Protocol Data Units sent.
STP BPDUs Received Spanning Tree Protocol Bridge Protocol Data Units received.
RSTP BPDUs Transmitted Rapid Spanning Tree Protocol Bridge Protocol Data Units sent.
RSTP BPDUs Received Rapid Spanning Tree Protocol Bridge Protocol Data Units received.
MSTP BPDUs Transmitted MSTP Bridge Protocol Data Units sent.
MSTP BPDUs Received Multiple Spanning Tree Protocol Bridge Protocol Data Units received.
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show spanning-tree interface 0/1
Hello Time..................................... Not Configured
Port Mode...................................... Enabled
BPDU Guard Effect.............................. Disabled
Root Guard..................................... FALSE
Loop Guard..................................... FALSE
TCN Guard...................................... FALSE
BPDU Filter Mode............................... Disabled
BPDU Flood Mode................................ Disabled
Auto Edge...................................... TRUE
Port Up Time Since Counters Last Cleared....... 8 day 3 hr 39 min 58 sec
STP BPDUs Transmitted.......................... 0
STP BPDUs Received............................. 0
RSTP BPDUs Transmitted......................... 0
RSTP BPDUs Received............................ 0
MSTP BPDUs Transmitted......................... 0
MSTP BPDUs Received............................ 0
(Extreme 220) (Routing) #
The following example shows CLI display output for the command.
(Extreme 220) (Routing) #show spanning-tree interface lag 1
Hello Time..................................... Not Configured
Port Mode...................................... Enabled
BPDU Guard Effect.............................. Disabled
Root Guard..................................... FALSE
Loop Guard..................................... FALSE
TCN Guard...................................... FALSE
BPDU Filter Mode............................... Disabled
BPDU Flood Mode................................ Disabled
Auto Edge...................................... TRUE
Port Up Time Since Counters Last Cleared....... 8 day 3 hr 42 min 5 sec
STP BPDUs Transmitted.......................... 0
STP BPDUs Received............................. 0
RSTP BPDUs Transmitted......................... 0
RSTP BPDUs Received............................ 0
MSTP BPDUs Transmitted......................... 0
MSTP BPDUs Received............................ 0
(Extreme 220) (Routing) #
show spanning-tree mst detailed
This command displays the detailed settings for an MST instance.
Switching Commands
ExtremeSwitching 200 Series: Command Reference Guide for version 01 .02.04.0007 306