Specifications

102 ExtremeWare 7.3.1b3 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
Configuring Diagnostics Mode Off
If you configure diagnostics mode OFF, and then execute the unconfigure switch all command,
when the switch returns to the active state the diagnostics mode is still set to OFF. The default
diagnostics mode should be
fastpost. To verify which diagnostics mode is set for the switch, use the
show switch command (1-97NL1).
Disable Remote Syslog Before Enabling IPARP Debug-Tracing
With remote syslog enabled, if you configure the IPARP debug-trace to level 2 or higher, the switch
hangs and is rebooted by the watchdog timer. To avoid this, disable the remote syslog prior to
configuring the debug-trace (PD2-110983505).
Bridging
Extended Diagnostics Does Not Include Backplane Connection
After running extended diagnostics on a slot, the mirror ptag will not include the backplane connection
(PD3-2016265).
Documentation
Summit48si LED Description Incorrect
The LED activity listed in Table 29 on page 85 of the Extreme Networks Consolidated “i” Series Hardware
Installation Guide is not correct. The Summit48si does not support 100/1000 Mbps Speed LEDs and
10/100 management port LEDs. Mini-GBIC port status LED information needs to be added to the table
(PD3-3523168).
reauth-period Range is Not Correct
The reauth-period range is not correct in the ExtremeWare 7.3 Software User Guide. The correct range is
600-60000 seconds (PD3-3455541, PD3-3455681).
EAPS is now supported with Basic Layer 3 License
With ExtremeWare 7.3, EAPS is now fully supported with the Basic Layer 3 license. However, this
ExtremeWare 7.3 licensing change is not included in the Software Licensing section of the ExtremeWare
7.3 Software User Guide. This change will be included in the next version of the ExtremeWare 7.3 Software
User Guide.
VRRP and ESRP Can Be Simultaneously Enabled
After ExtremeWare 6.2.1, VRRP and ESRP can be simultaneously enabled on the same switch. On page
352 of the ExtremeWare Software User Guide, Software Release 7.1.0, the second bulleted item at the top of
the page states that “VRRP and ESRP cannot be simultaneously enabled on the same switch,” which is
incorrect (PD2-233846470, PD2-233846479).