User's Manual

Installing the ExtremeWiNG
AP7662i/AP7662
Access Point
Overview of the AP7662i/AP7662
The AP7662 is an IP67 rated Access Point with 802.11ac dual band 2:2 radios.
The AP7662 is easy to install, lightweight, and is available in an internal
(AP7662i) and external (AP7662) antenna model. Each model includes 802.11
radios, an IoT radio, and a GPS radio. The AP7662 model comes in two models:
AP7662i and AP7662. In this document, the functionality, feature, and the
procedure applies to both the models when AP7662i/AP7662 is used.
The AP7662i/AP7662 model has the following features:
Radios: 2 radios (2.4GHz and 5GHz); 1 IoT/BLE/802.15.4 Radio (2.4 GHz)
•Console Port: RJ45
One RJ45, 10/100/1000 Ethernet Port (GE1) with PoE
One RJ45, 10/100/1000Mb Ethernet port (GE2)
IP67 Connectors on all ports
•LEDs: 4 (see Figure 1)
•One Reset button
Power: PoE 802.3af or 802.3at
GPS Receiver (will be supported via a future firmware release)
Antennas:
AP7662i - Five internal antennas (four band locked antennas and one
BLE antenna)
AP7662- Five external antennas (four single band antennas and one
BLE antenna)
Temperature: -40 to 70*C ambient temperature
Enclosure: Cast Aluminum base and Top
In Figure 1, the top image indicates AP7662i. Figure 2 shows the top and side
views of AP7662.
Figure 1 Top and Side Views of AP7662i
Figure 2 Top and Side Views of AP7662
Note: The AP7662i/AP7662 requires a minimum base firmware of
WiNG 5.9.1.
1
IoT/BLE Radio
2
Radio - 5 GHz
3
Radio - 2.4 GHz
4
Status
5
GE1 (PoE IN)
6
GE2
7
Console/Reset
8
Vent
1
IoT/BLE Radio
2
Radio - 5 GHz
3
Radio - 2.4 GHz
4
Status
5
GE1 (PoE IN)
6
GE2
7
Console/Reset
8
2.4 G - Antenna 1 and 2
LEDs on the Front of the AP
Amber LEDs indicate 5 GHz Wi-Fi Radio, Green LEDs indicate 2.4 GHz Wi-Fi
Radio, and Blue LED indicates the IoT Radio. The Status LED is ON only during
bootup.
For detailed installation information about the AP7662i/AP7662, see the
ExtremeWireless AP7662i/AP7662 Installation Guide.
Ta bl e 1 shows ways to power the AP7662i/AP7662.
Table 1 Powering the AP7662i/AP7662
Verifying the AP7662i/AP7662 Box Contents
Verify the contents of the box and ensure that the following items are
available:
Mounting and Connecting the AP
Use these instructions as guidelines for mounting and connecting the
AP7662i/AP7662 easily and safely.
The AP7662i/AP7662 mounting brackets are sold separately.
For more information about installing the optional bracket and the adapter,
see the ExtremeWireless AP7662i/AP7662 Installation Guide.
For installation videos of the AP, see www.extremenetworks.com/support/
Mounting the AP7662i/AP7662
Use these instructions as guidelines for mounting and connecting the
AP7662i/AP7662 easily and safely. The installation of the AP7662i/AP7662
should be performed by a professional installer to ensure proper operation
and compliance with local safety guidelines.
Attach the AP7662i/AP7662 to a surface that can support the AP and in an
environment it can withstand. It can be mounted to a wall, girder, ceiling, or
pole, and the surface material can be concrete, brick, wood, metal, or plastic.
Positioning the AP for Installation
Mount the AP so that the glands are on the side of the AP closest to the
ground, and not above the plastic cover. You must provide a 3-inch drip loop
on all cables.
Attach the Ground Wire
Use the M4 ground screw assembly, with the star washer, to attach the
ground wire’s ring terminal to the back of the AP. The wire should be as close
to the AP bottom as possible. Tighten the screw to a torque of 13.0-13.5 in-
lbs.
Mounting the AP7662i/AP7662 to a Wall
1 Using the mounting bracket as a guide, mark the location for the
mounting screws. The wall bracket provides eight attachment holes. Use
four (one in each corner). Place the bracket and mark the four hole
centers.
9
Vent
10
5G - Antenna 1
11
BLE/802.15.4 Antenna
12
5 G - Antenna 2
Power Source
Description
Power over
Ethernet
(PoE)
Power is provided through the RJ45 Ethernet port (GE1 port).
Table 2 Contents of the AP7662i/AP7662 Box
Quantity Item
1 AP7662i/AP7662 Quick Reference Guide
1 Cloud Quick Start Card
The following hardware is included:
1 M4 screw assembly with star washer
1 Ring terminal
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Note: Do not remove the dust cap until you need to install the BLE/
IoT antennas.
Note: Attach the H bracket after attaching the ground wire onto the
AP. Tighten the torque, tighten the screws, and attach the LAN
cable.
Note: The “H” type Mounting Bracket (WS-MBO-H01) is sold as a
separate accessory (ordering part #30519).
2 Drill four holes into the wall as follows:
for installing the AP on a masonry wall, use a 5/16” diameter bit.
for other materials, use the appropriate drill for the screws being used.
3 For masonry installations, drill at least 1/8” (3mm) past the depth of the
screw, or bolt, being used, and place four anchor assemblies into the
holes.
4 Attach the AP to the “H” Bracket:
a Use four M4 screw assemblies to attach the AP to the “H” bracket on
the side that does not have the PEM stand-offs.
b Tighten the four screws to a torque of 13.0-13.5 in-lbs.
Figure 3 Attaching the “H” Bracket to the AP
5 Secure the anchors to the wall, then secure the bracket to the anchors.
6 If using #10 screws, tighten them to a torque of 25 in-lbs. If using ¼”
screws, tighten them to 45 in-lbs.
Figure 4 AP7662i and AP7662 Wall Mount “H” Bracket
Mounting the AP7662i/AP7662 to a Pole
1 Determine the diameter of the pole.
For other pole diameters, provide your own stainless steel cable clamp.
The band must be ½” (12.7mm) wide.
2 Attach the AP to the “Pole Mount” bracket using 4 M4 screws. Tighten the
four screws to a torque of 13.0-13.5 in-lbs.
Figure 5 Attaching a Pole Bracket to the AP
3 Attach the cable clamp to the pole bracket. Open the cable clamp by
turning a flat bladed screwdriver counterclockwise. Then, insert the non-
clamp end into the pole bracket through the holes.
4 Put the metal band around the pole and insert it into the clamp. Turn the
clamp screw clockwise, tightening the band around the pole.
Note: The Pole Mounting Bracket (WS-MBO-POLE01) is sold as a
separate accessory (ordering part #30520).
Pole Diameter Cable Clamp Size
<= 2.5” (63.5mm) Use small cable clamp.
5” - 7” (178mm) Use large cable clamp
Note: It is easier to install both clamps before attaching to the pole.
Figure 6 AP with Mounting Bracket—Vertical Pole
Mounting the AP7662i/AP7662 to a Wall/Pole
using the WS-MBO-ART01 2 Axis Extension
Arm
You can mount the to AP7662i/AP7662 to a wall or a pole using a 10”
extension arm (WS-MBO-ART01, ordering part #30514). For mounting and
installation instructions, refer to the ExtremeWireless AP7662i/AP7662
Installation Guide.
Installing External Antennas
1 Professionally install the external antennas intended for area coverage.
For information about antenna selection and installation, refer to the
External Antenna Site Preparation and Installation Guide.
2 Attach the external antenna cables to the Standard Polarity Type-N
connectors on the AP7662i/AP7662.
Connecting a Power Supply to the AP7662i/AP7662
If you need to power the AP7662i/AP7662, you can do so my using the GE1
port on the AP. The power LED on the front face of the AP illuminates when
the device is powered on. Refer to the ExtremeWireless AP7662i/AP7662
Installation Guide for more information.
LAN/Console Connections
The AP7662i/AP7662 has two LAN (Ethernet) ports and a Console port. Refer
to Figure 1 and Figure 2 for the location of these ports. During administration
and maintenance through the LAN or Console, the AP must still have a power
connection through either an Ethernet PoE cable or a DC power supply.
Professional Installation Instruction
Installation personnel
This product is designed for specific application and needs to be installed by a
qualified personnel who has RF and related rule knowledge. The general user
shall not attempt to install or change the setting.
Installation location
The product shall be installed at a location where the radiating antenna can be
kept 20 cm for AP7662i and 35 cm for AP7662 (FCC) and 20 cm for AP7662i
and 42 cm for AP7662 (ISED) from nearby person in normal operation
condition to meet regulatory RF exposure requirement.
External antenna
Use only the antennas which have been approved by the applicant. The non-
approved antenna(s) may produce unwanted spurious or excessive RF
transmitting power which may lead to the violation of FCC/ISED limit and is
prohibited.
Installation procedure
Please refer to user’s manual for the detail.
Instructions d'installation professionnelle
Installation
Ce produit est destine a un usage specifique et doit etre installe par un
personnel qualifie maitrisant les radiofrequences et les regles s'y rapportant.
L'installation et les reglages ne doivent pas etre modifies par l'utilisateur final.
Emplacement d'installation
En usage normal, afin de respecter les exigences reglementaires concernant
l'exposition aux radiofrequences, ce produit doit etre installe de facon a
respecter une distance de 20cm pour AP7662i et 35 cm pour AP7662 (FCC)
et 20 cm pour AP7662i et 42 cm pour AP7662 (ISED) entre l'antenne
emettrice et les personnes.
Warning: Please carefully select the installation position and make sure that
the final output power does not exceed the limit set force in relevant rules. The
violation of the rule could lead to serious federal penalty.