User's Guide

Install the Waterproof Ethernet Cable Housing
Use the waterproof Ethernet cable housing to ensure a weatherproof seal for the Ethernet cable. Use the following procedures to install the hous-
ing.
1. Remove the sealing nut, claw, and the 2-part seal from the main body of the waterproof housing. Assemble these pieces around the Eth-
ernet cable in the order shown here:
2. Insert the Ethernet cable through the sealing nut and claw.
3. Take the seal apart, insert the cable between the two halves and reassemble the seal.
4. Insert the seal into the claw.
5. Insert the Ethernet connector into the main body and into the connector in the AP until the locking tab clicks into place. Make sure that
the small tabs on the claw fit into their counterparts on the main body.
6. Insert the seal and claw into the main body.
7. Screw the threaded nut onto the threaded main bodyto a torque of 10 inch-pounds.
8. Connect the other end of the Ethernet cable to a PoE injector or PoE-enabled switch.
Accessories
The following accessories are available for the AP460C, AP460S6C, and AP460S12C:
l
AH-ACC-PW-CBL-US: 6' 18 AWGuniversal power cordwith US plug
l
AH-ACC-PW-CBL-UK: 6' universal power cord with UK plug
AP460C, AP460S6C, AP460S12C Hardware Guide
6
AP460C, AP460S6C, AP460S12C Hardware Guide
6