PD4-1891009467,
PD4-1813024595
The show configuration ip-fix command does not return a configured flow-key if
you only configure src-ip/dest-ip. It also removes the non-IP flow-key.
PD4-1981255927,
PD4-1229634794
LACP packets are corrupted if the master port is mirrored on a SummitStack.
PD4-1986104397,
PD4-1933787279
The Node Manager process consumes excessive CPU usage on a backup MSM when
the system uptime reaches 994 days.
PD4-1963014380,
PD4-1409846531
The icmp-type match condition for ICMPv6 is not supported on Summit family and
BlackDiamond 8800 series switches.
PD4-1957143133,
PD4-1034683284
You cannot load a script using a flow-redirect configuration when a VLAN is down.
Workaround: Enable the VLAN and reconfigure the flow-redirect configuration.
PD4-1947222081,
PD4-1937692011
Copying large configuration files through SCP fails.
PD4-1917632053,
PD4-1857823251
A mismatch between a PIM multicast cache and a hardware binding results in traffic
loss.
PD4-1983606435,
PD4-1867264398
Running the save configuration command on an ExtremeXOS switch with a dual MSM,
or a stack with a backup node, causes a memory leak in the CfgMgr process.
PD4-1884535497 An LX mini-GBIC is incorrectly detected as an FX/LX mini-GBIC. This applies only to
Summit family switches and BlackDiamond 20800 series switches.
PD4-1701643346,
PD4-1677893691
A telnet connection may be abruptly closed by a switch when multiple telnet connections
are consecutively initiated in a short period of time.
PD4-1701643329,
PD4-1555469451
DHCP Option 82 packets are dropped if VPLS is enabled on an egress interface.
PD4-1851793216,
PD4-1323337297
A switch experiences memory depletion because of the HAL process when sending L2
traffic to a PVLAN with a continuous SA increment.
PD4-1846363979,
PD4-1821932411
The following directories are viewable in a browser window when Web HTTP is enabled:
/scripts
/images
/assets
/com
PD4-1702117524,
PD4-1417613295
The help text for the configure fdb vpls agingtime command displays the wrong
possible values.
PD4-1701643466,
PD4-1081411076
The CLI allows RIP configurations for L2 VLANs. After completing a RIP configuration,
running the show rip interface command causes the RIP process to die with signal 11.
PD4-1701643416,
PD4-1446804247
Multicast traffic is showing the incorrect dot1p replacement for CPU (slowpath) forwarded
packets with TOS bits set at 7.
PD4-1701643401,
PD4-1240910931
The cfgmgr crashes with signal 11 due to NULL pointer access.
PD4-1770347535,
PD4-1738654681
ExtremeXOS software does not correctly recognize the following mini-GBIC modules:
100FX/1000LX dual speed SFP, part number 4050-00020-02
100FX SFP, part number 4050-00030-03
PD4-1814536052,
PD4-1741274969
A switch crashes with soc_dma_done_desc in the NVRAM dump.
PD4-1758919554,
PD4-1517323275
The SSH process (exsshd) consumes 99% of CPU usage when running the clear
session command after abruptly closing an SSH session (xterm client only).
PD4-1758727774,
PD4-1695304439
After configuring an EMS xml-notification target, the name of the target is not included in
the output of the show configuration command.
Table 47: Resolved Issues, Platform-Specific and Feature PDs (Continued)