Installing Avaya Ethernet Routing Switch 3600 Series Release 6.0 NN47213-304 Issue 01.
© 2016-2017, Avaya, Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that the information in this document is complete and accurate at the time of printing, Avaya assumes no liability for any errors. Avaya reserves the right to make changes and corrections to the information in this document without the obligation to notify any person or organization of such changes.
documentation, Hosted Service, and the product provided by Avaya including the selection, arrangement and design of the content is owned either by Avaya or its licensors and is protected by copyright and other intellectual property laws including the sui generis rights relating to the protection of databases. You may not modify, copy, reproduce, republish, upload, post, transmit or distribute in any way any content, in whole or in part, including any code and software unless expressly authorized by Avaya.
Contents Chapter 1: Introduction............................................................................................................ 6 Purpose.................................................................................................................................. 6 Chapter 2: New in this document............................................................................................ 7 Chapter 3: Preinstallation checklist...................................................................
Contents Subscribing to e-notifications.................................................................................................. 43 January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Chapter 1: Introduction Purpose This document provides conceptual information and installation procedures for the switch hardware. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Chapter 2: New in this document Installing Avaya Ethernet Routing Switch 3600 Series, NN47213–304 is a new document. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Chapter 3: Preinstallation checklist Before you install the Avaya Ethernet Routing Switch 3600 Series, make sure that you complete the tasks in the preinstallation checklist. No. Task Description 1. Review the technical specification for For the physical, electrical, and the switch. Make sure that the area environmental specifications, see where you install the switch and Technical specifications on page 12. where it will operate meet the requirements. 2. Verify the AC power specifications.
No. Task Description path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode. See Installing ERS 3600 in an equipment rack on page 19. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Chapter 4: Installation preparation Switch models The following table describes the Avaya Ethernet Routing Switch 3600 Series models. All switch models support autopolarity. Model Key features Part number ERS3626GTS • 24 10/100/1000 ports AL3600?05-E6 • Two shared SFP ports • Two 1/10 Gigabit SFP+ ports operating in dual mode as uplink ports • Two 10 Gigabit SFP+ ports as either uplink or stacking ports • Non-PoE • Stackable ERS3626GTS-PWR+ • 24 10/100/1000 802.
Switch models Model Key features Part number ERS3650GTS-PWR+ • 48 10/100/1000 802.3at PoE ports and 2 shared SFP ports AL3600A16-E6 • Two 1/10 Gigabit SFP+ ports operating in dual mode as uplink ports • Two 10 Gigabit SFP+ ports as either uplink or stacking ports • Stackable Note: AC power cords are not packaged with the switch. Ensure you order the correct power cord for your region. For more information, see Supported power cords on page 16.
Installation preparation discharged to some connector pins but not others, or to some pins before others, which has the potential to damage the networking equipment. To protect the switch against ESD damage, take the following preventive measures before connecting any data cables to the device: • Always use antistatic wrist straps. Make sure the strap is adjusted to provide good skin contact.
Technical specifications Table 1: Physical specifications Switch Specification Height ERS 3650GTS, ERS 3650GTSPWR+, ERS 3626GTS, ERS 3626GTS-PWR+ 1U or 44.5 mm (1.75 inches) Width ERS 3626GTS, ERS 3626GTSPWR+, ERS 3650GTS, ERS 3650GTS-PWR 442 mm Depth ERS 3626GTS, ERS 3626GTSPWR+, ERS 3650GTS 280 mm ERS 3650GTS-PWR+ 380 mm ERS 3650GTS 3.93 kg ERS 3650GTS-PWR+ 6.25 kg ERS 3626GTS 3.57 kg ERS 3626GTS-PWR+ 4.
Installation preparation Environmental component Specification for ERS 3500 series Maximum Operating Altitude 10,000 ft Storage Altitude 10,000 ft Acoustic Noise (db) ERS3650GTS — 40.7dB@25C, 47.4dB@50C ERS3650GTS-PWR+ — 46.8dB@25C, 54.6dB@50C ERS3626GTS — 41.2dB@25C, 49.3dB@50C ERS3626GTS-PWR+ — 44.6dB@25C, 54.5dB@50C Miscellaneous Operating Considerations • At least 5cm (2") on each side of the switch unit for ventilation • Adequate power source within six feet.
Technical specifications Model Power supply Input power (margined by 10%) Power consumption (Thermal rating) Line voltage Watts Amps Watts BTUs/ hour 914.1W 100V-240V AC 903.51 8.21 163.91 559.26 914.1W 200-240VA C 858.16 3.79 120.06 409.
Installation preparation AC power cord specifications The following section outlines the AC power cord specifications for various countries. Ensure that you use the correct cord for your location. Table 7: International power cord specifications Country and plug description Specifications Continental Europe 220 or 230 VAC • CEE7 standard VII male plug 50 Hz • Harmonized cord (HAR marking on the outside of the cord jacket to comply with the CENELEC Harmonized Document HD-21) Single phase U.S.
Verifying the package contents AC power cords are not packaged with the switch. Ensure you order the correct power cord for your region. Order Code Description Region AA0020062E6 POWER CORD 3.05M IEC C13 TO NEMA 5-15P North America AA0020063E6 POWER CORD 2.5M IEC C13 TO BS1363 United Kingdom AA0020064E6 POWER CORD 2.5M IEC C13 TO CEE 7/7 European Union AA0020065E6 POWER CORD 2.5M IEC C13 TO CEI 23-16 Italy AA0020066E6 POWER CORD 2.5M IEC C13 TO GB 2099.
Installation preparation Note: AC power cords are not packaged with the switch. Ensure you order the correct power cord for your region. Connecting AC power Before you begin • To connect AC power to the switch an appropriate AC power cord is required. Ensure the switch power supply supports AC power input. Danger: Use only power cords with a grounding path. Without a proper ground, a person who touches the switch is in danger of receiving an electrical shock.
Chapter 5: Installing ERS 3600 in an equipment rack Installing ERS 3600 switch in an equipment rack Before you begin Tool requirements • Phillips screwdriver to attach brackets to the switch and the switch to the rack Rack requirements • Space of 2.8 inches (7.1 cm) for each 3626 or 3650 model is available in an E1A or 1EC standard 19 inch (48.2 cm) equipment rack and T1A 23 inch (58.5 cm) equipment rack.
Installing ERS 3600 in an equipment rack 3. Slide the switch into the rack. Insert and tighten the rack-mount screws. 4. Verify that the switch is securely fastened to the rack.
Single and multiple switch arrangements ERS3650 switches. With SFP+ 10Gb stacking cables, the stack bandwidth is 2 ports x 10Gbps/port x 2 directions = 40 Gbps. Standalone arrangement Any one switch can operate in a standalone configuration. You can add more switches as your traffic increases. Stack arrangement You connect the switches in the stack by the stack connectors. You designate one unit as the base unit by setting a switch on the back panel.
Installing ERS 3600 in an equipment rack Unit Select switch in the base unit position. All other switches in the stack must have the Unit Select switch in the up position which designates them as non-base units. During the initial installation of the stack, the software automatically determines the physical order of all units in the stack according to the position of the base unit within the stack.
Single and multiple switch arrangements is designated Unit 2. The stack is wired downward through the units and the system continues to number in this manner throughout the stack. In this configuration, the base unit discovers the stack in a cascade down (stack down) direction. Figure 4: Cascade down configuration Note: Return cable length might vary depending on unit spacing. Ensure you order the proper length return cable to provide adequate strain relief.
Installing ERS 3600 in an equipment rack Cascade up In a cascade up (stack up) configuration, the base unit is physically located as the top unit in the stack. The cable connected to the Cascade Down connector of the base unit terminates in the Cascade Up connector physically located at the bottom of the stack. This next unit is designated Unit 2. The stack is wired upward through the units and the system continues to number in this manner throughout the stack.
Identifying cables to use with the Ethernet Routing Switch In addition to increasing bandwidth, the software uses the cables to provide two paths between units. If one path breaks the data travels over the remaining path with half the normal inter-switch bandwidth. Stack configuration You can change base unit switches with switches on (hot), but changes do not take affect until switches are rebooted. Selecting a base unit Procedure 1. Determine which unit will be the base unit. 2.
Installing ERS 3600 in an equipment rack Required cable Description Standard, ANSI/TIA/EIA 568-B fitted with an RJ-45 Module Jack. Console Port Serial cable with a DB-9 female connector on both ends. The maximum length for the console port cable is 25 feet (8.3 meters). Shared SFP Transceiver Ports Varies with the installed SFP Transceiver. Refer to the documentation that was shipped with the SFP Transceiver for specifications. USB Ports USB 2.
Connecting a transceiver to the switch or switch stack Supported optical devices Use optical devices to achieve high-bit-rate communications and long transmission distances. The following section describes the supported optical devices on the switches. Important: Avaya recommends that you use Avaya branded SFP and SFP+ transceivers as they undergo extensive qualification and testing. Avaya is not responsible for any problems that arise from using non-Avaya branded SFP and SFP+ transceivers.
Installing ERS 3600 in an equipment rack Table 8: SFP transceivers Model Description Part number Important: Avaya supports SFP transceivers with the following part numbers: AA1419013–E5, AA1419014–E5, AA1419015–E5, and AA1419025–E5 to AA1419040–E5. However, Avaya strongly recommends using the newer DDI versions of these SFP transceivers.
Locating end of sale notices Model Description Part number 10GBASE-CX SFP+ 2-pair twinaxial copper cable that plugs into the SFP+ socket and connects two 10-gigabit ports SFP+ DAC 3 meter AA1403019–E6 10GBASE-CX SFP+ 2-pair twinaxial copper cable that plugs into the SFP+ socket and connects two 10-gigabit ports SFP+ DAC 5 meter AA1403020–E6 Operating power considerations When you connect the device to collocated equipment, ensure that enough optical attenuation exists to avoid overloading the rece
Installing ERS 3600 in an equipment rack Important: When used as Stacking ports, the LEDs on the left of the switch indicate Stack port status. The Stack Up and Stack Down LEDs are updated as the Stack ports become active or idle. Their local port LEDs do not indicate Stack port status. When used as Standalone ports, the local LEDs indicate port status, like all other ports. Before you begin Perform the following tasks before checking the status LEDs.
Checking status LEDs to verify switch installation LED State Description UP/Down Off No Stack-up or Stack-down connection is detected. Amber (Solid) A Stack-up or Stack-down cable is detected, but adjacency has not been completed. Green (Solid) The unit has formed a neighbor with an adjacent unit over the Stack-up or Stack-down cables. Off The unit is operating in a standalone mode, or not the stack base unit. Amber (Solid) The unit is operating as the Temporary Base Unit.
Installing ERS 3600 in an equipment rack Label Rx Color/Status Description Solid Amber SFP detected and Link established. Amber / blinking SFP link established and transmit activity detected. Green / slow blinking RX & TX blinking together in a slow pattern indicate that the port has been disabled by the software. Off No link established. Solid Green SFP+ detected and link established. Green / blinking SFP+ link established and receive activity detected.
IP address information configuration Accessing the console menu Procedure 1. Connect a terminal to the console port of the switch. 2. Set the terminal protocol on the terminal or terminal emulation program to VT100 and VT100/ANSI. 3. Connect to the switch using the terminal or terminal emulation application. 4. After the Avaya banner is displayed, press CTRL + Y to display the main menu.
Installing ERS 3600 in an equipment rack Property Value Parity None Flow Control None Assigning IP parameters using Enterprise Device Manager Procedure 1. Connect a computer to the switch through a data port using a standard RJ-45 network cable. 2. Open a Web browser on the attached computer. 3. Enter the factory default IP address of the switch in the following format: http:// . 4. In the navigation pane of the Enterprise Device Manager Interface, click Administration > Quick Start. 5.
Chapter 6: Installation reference Console and management connections The front panel of the switch contains the Status LEDs, Console port, and a USB 2.1 port. The rear panel of the switch contains the Base Unit switch. Console port The console port is the RJ45 port with a blue border outline. You can use the console port to establish a management terminal connection to the switch. You can use an RJ45 to DB-9 cable, or a DB-9 to RJ45 adapter to connect the switch console port to your management terminal.
Installation reference RJ45 console port pin-out Signal Requirement 6 RXD (receive data) Mandatory 7 DSR (data set ready) Optional 8 CTS (clear to send) Optional (can be swapped or linked with pin USB port The USB port is a Standard Type-A female USB 2.1 port. The switch provides USB host functionality and can support USB flash drives. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Chapter 7: Safety messages Caution: When mounting this device in a rack, do not stack units directly on top of one another in the rack. Each unit must be secured to the rack with appropriate mounting brackets. Mounting brackets are not designed to support multiple units. Important: Achtung: Wenn diese Einheit in einem Rack montiert wird, muß ein gewisser Abstand zur nächsten Einheit gelassen werden. Jede Einheit muß mit geeignetem Befestigungsmaterial gesichert werden.
Safety messages Caution: If you are not installing a module in the slot, be sure to keep the metal cover plate in place over the slot. Removing the cover plate impedes airflow and proper cooling of the unit. Important: Achtung: Wenn Sie kein Modul im Schacht verwenden, muß die Metallabdeckung über dem Schacht montiert sein. Eine Entfernung der Abdeckung führt zu einer Verschlechterung der Luftzirkulation und damit zu einer nicht ausreichenden Kühlung der Einheit.
Warning: Disconnecting the AC power cord is the only way to turn off AC power to this device. Always connect the AC power cord in a location that can be reached quickly and safely in case of an emergency. Important: Warnung: Das Gerät kann nur durch Ziehen des Netzsteckers ausgeschaltet werden. Schließen Sie das Netzkabel an einer Steckdose an, die in Notfällen schnell und sicher zugänglich ist.
Safety messages Important: Peligro: Utilice únicamente cables de alimentación con toma de tierra. De lo contrario, al tocar el interruptor puede recibir una descarga eléctrica. Si no hay un circuito de toma de tierra en el enchufe, puede producirse un exceso de emisiones. Important: Pericolo: Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per la messa a terra. Senza un’adeguata messa a terra, chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica.
Chapter 8: Related Resources Support Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation, product notices, and knowledge articles. You can also search for release notes, downloads, and resolutions to issues. Use the online service request system to create a service request. Chat with live agents to get answers to questions, or request an agent to connect you to a support team if an issue requires additional expertise.
Related Resources Viewing Avaya Mentor videos Avaya Mentor videos provide technical content on how to install, configure, and troubleshoot Avaya products. About this task Videos are available on the Avaya Support website, listed under the video document type, and on the Avaya-run channel on YouTube. Procedure • To find videos on the Avaya Support website, go to http://support.avaya.com and perform one of the following actions: - In Search, type Avaya Mentor Videos to see a list of the available videos.
Subscribing to e-notifications 3. In the Search dialog box, select the option In the index named .pdx. 4. Enter a search word or phrase. 5. Select any of the following to narrow your search: • Whole Words Only • Case-Sensitive • Include Bookmarks • Include Comments 6. Click Search. The search results show the number of documents and instances found. You can sort the search results by Relevance Ranking, Date Modified, Filename, or Location. The default is Relevance Ranking.
Related Resources 6. Click OK. 7. In the PRODUCT NOTIFICATIONS area, click Add More Products. 8. Scroll through the list, and then select the product name. 9. Select a release version. 10. Select the check box next to the required documentation types. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Subscribing to e-notifications 11. Click Submit. January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.
Index S support .................................................................................41 V videos .................................................................................. 42 January 2017 Installing Avaya Ethernet Routing Switch 3600 Series Comments on this document? infodev@avaya.