Configuration Guide

Table Of Contents
20.1.9 SwitchedUNI Configuration
©2021 Extreme Networks, Inc. All rights reserved
October 2021
10
4
Please note that switches 7001 and 7002 are VSP7000 switches
config terminal
vlan create <vlan id> type spbm-switchedUni
i-sid
<ISID: 0..16000000> vlan <vlan-id> port <port member>
Although you can use any number from 1 to 16,777,215 as an ISID value, it is recommended
not to use a value from 16,000,001 to 16,777,215. This range is used for Multicast over SPB.
Switched UNI
configure terminal
vlan ports 1/15 tagging tagall
vlan create 18 type spbm-switchedUni
vlan create 20 type spbm-switchedUni
i-sid 10018 vlan 18 port 1/15
i-sid 10018 vlan 20 port 1/15
vlan members remove 1 1/15
configure terminal
vlan ports 1/15 tagging tagall
vlan create 18 type spbm-switchedUni
i-sid 10018 vlan 18 port 1/15
vlan members remove 1 1/15