Configuration Guide
Table Of Contents
- Table of Contents
- 1. Overview
- 2. SPB Terminology
- 3. SPB Support Topologies
- 4. UNI Types
- 5. Summary of SPB Features and ProductRelease Matrix
- 6. SPB Feature and License Matrix
- 7. Scaling
- 8. Migration & Upgrades
- 9. Field Introduction & Support Specifications
- 10. VSP 7000 – Fabric Interconnect
- 11. ISIS Metrics - Optional
- 12. ISIS Accept Policy
- 13. ISIS External Metric
- 14. SPB over L2/L3 networks
- 15. Fabric Attach
- 16. SPB SMLT BEB Design Best Practices
- 17. SPB NNI SMLT – migrating existing SMLT network to SPB
- 18. IS-IS TLV
- 19. SPB Best Practices
- 20. SPB Configuration
- 20.1 SPB Configuration
- 20.1.1 ERS 8800 – Converting from CLI to ACLI
- 20.1.2 SPB and IS-IS Core Configuration
- 20.1.3 SPB NNI Interface Configuration
- 20.1.4 CFM Configuration
- 20.1.5 VSP 7000 – Fabric Interconnect Mesh
- 20.1.6 SMLT – Normal IST
- 20.1.7 SMLT - Virtual IST (vIST)
- 20.1.8 L2VSN Configuration
- 20.1.9 SwitchedUNI Configuration
- 20.1.10 Flex UNI Switched Configuration
- 20.1.11 Transparent UNI Configuration
- 20.1.12 Private VLAN (ETREE) Configuration
- 20.1.13 L3VSN Configuration
- 20.1.14 L3VSN – leaking routes between VRF’s
- 20.1.15 IP Shortcuts
- 20.1.16 IP Shortcut– Suppress IST Network
- 20.1.17 IP Shortcuts – leaking routes between GRT and VRF
- 20.1.18 IP Shortcuts – redistribution of ISIS and OSPF
- 20.1.19 Inter-VSN Routing
- 20.1.20 IPv6 Shortcuts
- 20.1.21 SPB Multicast Configuration
- 20.1.22 Multicast 239.255.255/24 – UPnP Filtering
- 20.1.23 Connectivity Fault Management (CFM) Configuration
- 20.1.24 CFM Configuration Example – 7.1.1.x or higher
- 20.1.25 Fabric Extend Configuration
- 20.1.26 ONA: Assigning a Static IP address to the Open Network Adapter
- 20.1.27 Fabric Extend over Routed Infrastructure using VRF to interconnect to routed network
- 20.1.28 Fabric Extend over Routed Infrastructure using GRT to interconnect to routed network
- 20.1.29 Fabric Extend over E-LAN/VPLS (L2) network using Layer 3 over Layer 2 tunneling using VSP 4000
- 20.1.30 Fabric Extend over E-LAN/VPLS (L2) network using Layer 3 over Layer 2 tunneling with VSP8000 orVSP7200
- 20.1.31 Fabric Extend over E-LAN/VPLS (L2) network using VLAN Tunnels
- 20.1.32 Fabric Attach Configuration
- 20.1.33 Identity Engines – Attribute Details
- 20.1.34 Fabric Attach Base Configuration – Adding a FA Proxy and FA Server
- 20.1.34.1 Fabric Attach – Adding a Platform VLAN on FA Server forManagement VLAN
- 20.1.34.2 Fabric Attach – Adding a L2VSN Service
- 20.1.34.3 Fabric Attach – Adding a L3VSN Service
- 20.1.34.4 Fabric Attach - Adding a WLAN 9100 FA Client with EAPDevice authentication via Identity Engines
- 20.1.34.5 Fabric Attach – Changing the FA authentication key
- 20.1.35 Fabric Attach Proxy Standalone
- 20.2 Using EDM
- 20.1 SPB Configuration
- 21. VLAN and ISID Restrictions using TACACS+via Identity Engines
- 22. Configuration Examples
- 22.1 SPB – Core Setup
- 22.1.1 Configuration
- 22.1.1.1 Configuration Mode
- 22.1.1.2 Auto Save
- 22.1.1.3 VSP 7000 – Rear Port Mode
- 22.1.1.4 Option: Change Spanning Tree mode to MSTP
- 22.1.1.5 System Name
- 22.1.1.6 Option – Configure out-of-band management interface
- 22.1.1.7 Enable VLACP Globally
- 22.1.1.8 IST Configuration – SMLT Cluster switch 4001 & 4002, 9001 & 9002 and 8005 & 8006
- 22.1.1.9 IS-IS and SPB Global Configuration
- 22.1.1.10 IS-IS SPB Interface Configuration
- 22.1.1.11 Remove default VLAN from all SPB ports
- 22.1.1.12 Other best practice items – VLACP and discard untagged frames
- 22.1.1.13 IST Configuration – SMLT Cluster switch 7001 & 7002
- 22.1.1.14 ISIS L1-metric – Optional
- 22.1.1.15 Connectivity Fault Management (CFM) Configuration
- 22.1.1.16 QoS
- 22.1.2 Configuration using EDM – Using 8005 as an example
- 22.1.3 Verify Operations
- 22.1.1 Configuration
- 22.2 SMLT Configuration
- 22.3 SPB L2 VSN Configuration
- 22.4 VSP 7000 & ERS 4800 – In-band Management via L2VSN
- 22.5 Multicast over L2VSN
- 22.6 Inter VSN Routing
- 22.7 Inter-ISID Configuration
- 22.7.1 VRF configuration
- 22.7.2 Verification
- 22.8 SPB L3 VSN – SMLT
- 22.9 Extending L3VSN to the VSP 7000 Cluster via L2VSN
- 22.10 Multicast over L3VSN
- 22.11 SPB IP Shortcuts
- 22.12 Multicast over IP Shortcuts
- 22.1 SPB – Core Setup
- 23. Restrictions and Limitations
- 24. Reference Documentation
©2021 Extreme Networks, Inc. All rights reserved
October 2021
213
4802#show eapol multihost interface 11
Port: 11
MultiHost Status : Enabled
Total Maximum Number of Clients : 1
Maximum Number of EAP Clients : 1
Maximum Number of Non-EAP Clients : 1
Allow Local Non-EAP Clients : Disabled
Non-EAP RADIUS Authentication : Enabled
Non-EAP AutoLearned After Single Auth (MHSA) : Enabled
Non-EAP DHCP Phone Authentication : Disabled
EAPoL Request Packet Generation Mode : Multicast
EAP RADIUS Assigned VLANs : Disabled
Non-EAP RADIUS Assigned VLANs : Disabled
EAP Protocol : Enabled
Use Most Recent RADIUS Assigned VLAN : Disabled
Block Different RADIUS Assigned VLAN Authentication : Disabled
ADAC Non-EAP Phone Authentication : Disabled
MHSA No limit Non-EAP Authentication : Enabled
A17142803390B# show fabric-attach status
Fabric Attach Status
State enabled
Element Type FA Client - Wireless Access Point Type 1
Element State untagged
Management VLAN 0
Element Gig1 MAC Address 64:a7:dd:03:39:03
Element Gig2 MAC Address 64:a7:dd:03:39:04
Message Auth Key set
A17142803390B# show fabric-attach elements
Fabric Attach
Interface
Elements
Element IP
Element Type
Mgmt VLAN
Element MAC
Last Update
d
gig1
10.5.110.254
FA Proxy
1100
cc:f9:54:b4:ac:00
15
A17142803390B#
LLDP List
show lld
p
neighbors
Hostname IP Address Model
Interface
VLAN Capabilities
4802 10.12.110.254
Port 11
Bridge Router
WAP 9132 Verify Operations - Assuming a WAP 9132 is connected to port 11 on the Proxy
Standalone switch and using SSH to connect the WAP 9132