Configuration Guide

Table Of Contents
SPBM Configuration – ERS 8800: Use the show isis system-id command on the peer
cluster switch to get the smlt-peer-system-id value for the SMLT cluster switches
©2021 Extreme Networks, Inc. All rights reserved
October 2021
242
8003:5(config)#spbm
8003:5(config)#router isis
8003:5(config-isis)#spbm 1
8003:5(config-isis)#spbm 1 nick-name 0.80.03
8003:5(config-isis)#spbm 1 b-vid 4051-4052 primary 4051
8003:5(config-isis)#manual-area 49.0001
8003:5(config-isis)#exit
8003:5(config)#vlan create 4051 name BVLAN-1 type spbm-bvlan
8003:5(config)#vlan create 4052 name BVLAN-2 type spbm-bvlan
8003:5(config)#router isis enable
For switches 8004, 8005, 8006, and 8007, use the same configuration as above except for
the items shown below. Note that bridges 8005 and 8006 also has the additional
configuration to support SPB over SMLT.
8004:5(config-isis)#spbm
1
nick-name 0.80.04
8005:5(config-isis)#spbm
1
nick-name 0.80.05
8005:5(config-isis)#spbm
1
smlt-peer-system-id 001e.1f48.f3df
8006:5(config-isis)#spbm
1
nick-name 0.80.06
8006:5(config-isis)#spbm
1
smlt-peer-system-id 0024.43b4.e3df
8007:5(config-isis)#spbm
1