Configuration Guide

Table Of Contents
©2021 Extreme Networks, Inc. All rights reserved
October 2021
278
Option Verify
IS-IS SPB
B-VID
PRIMARY VLAN
The B-VLAN is displayed should be 4051 and 4052 where the primary
B-VLAN should be 4051
NICK
NAME
The value displayed should be as follows per this configuration
example:
4001: 0.40.01
4001: 0.40.02
7001: 0.70.01
7002: 0.70.02
7003: 0.70.03
7004: 0.70.04
9001: 0.90.01
9002: 0.90.02
8003: 0.80.03
8004: 0.80.04
8005: 0.80.05
8006: 0.80.06
8007: 0.80.07
SPB Unicast FIB
FIB ENTRY For each host, there should be a destination forwarding entry via both
B-VLANs. Note that the default metric is 10 for all links.
22.1.3.4 Verify IS-IS Link-State Database
Step 1 – Show IS-IS LSDB
show isis lsdb
Results: From switches 4001 and 9001
4001:
================================================================================
ISIS LSDB
================================================================================
L
SP ID LEVEL LIFETIME SEQNUM CHKSUM HOST-NAME
0080.2dbe.23df.00-00
1
748 0x1545 0xbc63 8003
00e0.7bbc.23df.00-00
1
1068 0x1191 0xbc2 8004
0
024.43b4.e3df.00-00
1
978 0xae9 0x8e34 8005
0
01e.1f48.f3df.00-00
1
930 0x1555 0x90c3 8006
0
0e0.7bb3.07df.00-00
1
1090 0x23c 0x1dcb 8007