Configuration Guide

Table Of Contents
©2021 Extreme Networks, Inc. All rights reserved
October 2021
334
===============================================================================
VID IP MAC ADMIN OPER HDTMR HUTMR
2255
VID
192.168.33.2
SMLT ID
00:1e:1f:48:f2:22 Enable
SLT
Up
ID
60 infinity
2255
VID
5
IPv6
MAC
129
ADMIN OPER
HDTMR
HUTMR
VID SMLT ID
SLT ID
===============================================================================
Ip Rsmlt Peer Info - VRF blue
===============================================================================
VID IP MAC ADMIN OPER HDTMR HUTMR
2255 192.168.33.1 00:24:43:b4:e2:23 Enable Up 60 infinity
VID HDT REMAIN HUT REMAIN SMLT ID
SLT ID
2255
VID
60
IPv6
infinity
MAC
5
ADMIN
OPER
HDTMR
HUTMR
129
VID HDT REMAIN HUT REMAIN SMLT ID
SLT ID
On each SMLT cluster switch, verify the following:
Option Verify
VID The value displayed should be 2254 for vrf red and 2255 for vrf blue as
per the VLAN ID used in this configuration example.
ADMIN The value displayed should be Enable which indicates that RSMLT has
been enabled for this interface
OPER Should be displayed as Up indicating that RSMLT is operational
HUTMR Should be displayed as infinity as we configured this interface as a
RSMLT Edge interface with a holdup-timer timer value of 9999
SLT ID The value displayed should be 129 for SMLT cluster 8005 & 8005 as
per the SMLT ID’s used in this example