Power Specifications
(Base Unit fully Equipped with Power Supplies)
ERS 5928GTS
• Up to 77.2W, up to 0.43A, and up to 263.4BTU/hr @ 200-240VAC
• Up to 77.4W, up to 0.7A, and up to 264.0BTU/hr @ 100-110VAC
• 52.2W power consumption at idle, and 56.7W under typical trac load
ERS 5928GTS-uPWR
• Up to 1,616.0W, up to 7.1A, and up to 588.0BTU/hr @ 200-240VAC
• Up to 1,662.0W, up to 14.5A, and up to 744.0BTU/hr @ 100-110VAC
• 46.0W power consumption at idle, and 50.7W under typical trac load
(excluding PoE draw)
ERS 5928MTS-uPWR
• Up to 1,693.3W, up to 8.0A, and up to 872.4BTU/hr @200-240VAC
• Up to 1,810.2W up to 15.8A, and up to 1,237.5BTU/hr @100-110VAC
• 114.49W power consumption at idle, and 119.0W under typical trac load
(excluding PoE draw)
ERS 5952GTS
• Up to 88.6W, up to 0.46A, and up to 302.3BTU/hr @ 200-240VAC
• Up to 90.0W, up to 0.78A, and up to 307.1BTU/hr @ 100-110VAC
• 60.4W power consumption at idle, and 69.0W under typical trac load
ERS 5952GTS-PWR+
• Up to 1,662.0W, up to 7.12A, and up to 600.5BTU/hr @ 200-240VAC
• Up to 1,665.0W, up to 14.58A, and up to 754.1BTU/hr @ 100-110VAC
• 56.5W power consumption at idle, and 65.6W under typical trac load
(excluding PoE draw)
ERS 59100GTS
• Up to 182.6W, up to 1.0A, and up to 623.1BTU/hr @200-240VAC
• Up to 183.9W, up to 1.6A, and up to 627.5BTU/hr @100-110VAC
• 92.0W power consumption at idle, and 111.0W under typical trac load
ERS 59100GTS-PWR+
• Up to 3,218.9W, up to 14.1A, and up to 1,099.0BTU/hr @200-240VAC
• Up to 3,327.2W, up to 29.0A, and up to 1,473.9BTU/hr @100-110VAC
• 97.1W power consumption at idle, and 117.7W under typical trac load
(excluding PoE draw)Storage Humidity:
Environmental Specifications
Operating Temperature 0°C to 50°C (32°F to 122°F); the 5928MTS-uPWR model supports 0°C to 45°C in Back-to-Front airflow configuration
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 0 to 95% maximum relative humidity, non-condensing; 0 to 85% for the 5928MTS-uPWR
Storage Humidity 10 to 90% maximum relative humidity, non-condensing; 10 to 85% for the 5928MTS-uPWR
Operating Altitude 0 to 3,048m (0 to 10,000ft) maximum Storage altitude: 0 to 12,192m (0 to 40,000ft) maximum
Acoustic Noise
• Less than 52dbA at 25°C
• Less than 60dbA at 50°C
Safety Agency Approvals
• IEC 60950 International CB Certification
• EN 60950-1 Europe Safety (CE): CB Scheme Certification with
Member Deviations
• UL 60950-1 USA Safety
• CSA-C22.2, #60950-1 Canada Safety
• NOM Mexico Safety
• EN 60950-1 Japan Safety
• Anatel Brazilian Safety
• ACMA-RCM Australia Safety
• Customs Union/EAC Safety of Low-Voltage Equipment Certification
• CCC and MIIT China Safety
• CNS 14336-1 Taiwan BSMI Safety
• UL 1069 Hospital Signaling and Nurse Call Equipment (relevant to PWR
units only)
Electromagnetic Emissions
and Immunity
• CISPR 22 International EMC Emissions
• CIRPR 24 International EMC Immunity
• FCC part 15B, Class A USA EMC Emissions
• ICES-003 Class A Canadian EMC Emissions
• VCCI Japan EMC Emissions
• EN 55022 Class A, CISPR 22 European EMC Emissions (CE)
• EN 55024, CISPR 24 including EN 61000-4-2, 4-3, 4-4, 4-5, 4-6, 4-8 and
4-11 European EMC Immunity (CE)
• ACMA-RCM Mark
• Australia EMC Emissions
• Anatel Brazilian EMC Certification
• Customs Union/EAC EMC Certification
• CCC and MIIT China EMC Certification
• KC mark: EMI and EMS Korean EMC Certification
• CNS 13438 Taiwan BSMI EMC
MTBF Values
(Base Unit with Single Power Supply)
• ERS 5928GTS – up to 248,756 hours (28.40 years)
• ERS 5928GTS-uPWR – up to 254,165 (29.01 years)
• ERS 5928MTS-uPWR up to 243,895 (27.84 years)
• ERS 5952GTS – up to 241,078 hours (27.52 years)
• ERS 5952GTS-PWR+ – up to 239,731 hours (27.37 years)
• ERS 59100GTS up to 150,386 hours (17.67 years)
• ERS 59100GTS-PWR+ up to 145,094 hours (16.56 years)