Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
79
Resolved Issues in ExtremeXOS 12.4.4-patch1-5
The following issues were resolved in ExtremeXOS 12.4.4-patch1-5. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.6, ExtremeXOS 12.2.2-patch1-12, and ExtremeXOS 12.3.6. For information on those
fixes, see the release notes for the specific release.
Resolved Issues in ExtremeXOS 12.4.4-patch1-4
The following issues were resolved in ExtremeXOS 12.4.4-patch1-4. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.6, ExtremeXOS 12.2.2-patch1-12, and ExtremeXOS 12.3.6. For information on those
fixes, see the release notes for the specific release.
Table 43: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-2093639778 After making STP configuration changes on a switch, RSTP root bridges send hello
BPDU every 4 seconds when the switch is configured for every 2 seconds.
Table 44: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1970043078 In a private VLAN, a static IP ARP entry is incorrectly associated with a subscriber
VLAN.
PD4-1437616911 When running the configure ports medium <fiber/copper> auto <on/off>
speed <speed> duplex <half/full> command, the command is not retained
when a switch reboots.
PD4-2028980655,
PD4-1900406099
In a private VLAN, broadcast packets are not forwarded after a network VLAN port is
changed to a shared port.
PD4-1990369509,
PD4-1751958424
In CLI scripting, $READ inside a loop is not working and displays the following error:
Incorrect READ syntax Error: Read syntax
PD4-1927210571 A supplicant attached to a network login port on an Extreme switch is not receiving
EAPS FAIL messages if RADIUS is unavailable.
PD4-2073557597,
PD4-2053914004
Traffic on an ESRP master or member VLAN is forwarded in slowpath, which results in
high CPU utilization when hardware ARP limits are exceeded.
PD4-2033837826,
PD4-1441107715
The FDB process dies with signal 11 when creating a blackhole entry for a MAC address
authenticated by network login.
BlackDiamond 8800 Series Switch
PD4-2049272668 L2 traffic is being flooded even though the destination MAC is learned on the port.
BlackDiamond 12800 Series Switch
PD4-2068851844 A port is removed from a load sharing group after an MSM failover after increasing the
number of multicast data packets hitting a CPU because of an invalid rendezvous point
(RP), or other failure.