Resolved Issues in ExtremeXOS 12.4.3
The following issues were resolved in ExtremeXOS 12.4.3. ExtremeXOS 12.4 includes all fixes up to and
including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.5, ExtremeXOS 12.2.2,
and ExtremeXOS 12.3.6. For information on those fixes, see the release notes for the specific release.
SummitStack
PD4-1814857343,
PD4-580973662
Unconfiguring a management IP address removes the default route configured using the
configure stacking alternate-ip-address [<ipaddress> <netmask> |
<ipNetmask>] <gateway> automatic command.
IGMP
PD4-1299135401 Multicast traffic is dropped with an EAPS shared port configuration during an EAPS
topology change.
OSPF
PD4-1842342899,
PD4-1524171924
Not all of the AS external routes in OSPF are getting installed in the route table.
Table 48: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1084698943,
PD4-977234454
Configuring UPM profiles to include the show port info detail command results in
the show profile history command output showing the status as failed.
PD3-71725881 When configuring an optional name for the time zone/DST, the time zone name truncates
at seven characters. The system default is six characters.
PD4-1789156831 The following note has been added to the "Managing DHCP/BOOTP Relay" section of the
"IP Unicast" chapter of the ExtremeXOS Concepts Guide. It has also been added to the
Usage Guidelines for the enable bootprelay command in the ExtremeXOS Command
Reference Guide:
Note: If DHCP/BOOTP Relay is enabled on a per VLAN basis, make sure it is enabled on
both the client-side and server-side VLANs.
PD4-1741718115,
PD4-1107340401
When TACACS is used for user authentication, the log message shows the wrong IP
address of the user being authenticated.
PD4-1758727874,
PD4-1517323275
The SSH process (exsshd) consumes 99% of CPU usage when running the clear
session command after abruptly closing an SSH session (xterm client only).
PD4-1741274969 A switch crashes with soc_dma_done_desc in the NVRAM dump.
BlackDiamond 8800 Series Switch
PD4-1801215011,
PD4-1727668151
On BlackDiamond 8800 series switches, SummitStack, and Summit family switches that
are supported by this software release, meters are a per-VLAN resource. For example, if
you assign a 50 Mbps meter to a VLAN, the total throughput for all ports in that VLAN is
limited to 50 Mbps.
PD4-1703399239,
PD4-962149281
The output for the show configuration etmon | detail command does not show
the disabled sFlow port.
Table 47: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description