Installation Guide
Table Of Contents
- Table of Contents
- Preface
- ExtremeSwitching 5520 Series Overview
- Port Partitioning
- Power Supplies for Use with Your Switch
- Expansion Modules
- Site Preparation
- Building Stacks
- Installing Your Switch
- Activating and Verifying the Switch
- Installing Expansion Modules
- Installing a V300 Virtual Port Extender
- Install a V300 Virtual Port Extender on a Wall
- Install a V300 Virtual Port Extender Under or on a Table Surface
- Install a V300 Virtual Port Extender in a VESA Mount
- Install a V300 in a Single Rack Mount
- Install a V300 in a Dual Rack Mount
- Install a V300 in a DIN Rail Mount
- Install a V300-8P-2T-W Model in a Single or Dual Rack Mount
- Installing a V300-8P-2T-W Model in a DIN Rail Mount
- Connecting the V300 Virtual Port Extender to Power
- Installing a V400 Virtual Port Extender
- Installing a Half-Duplex to Full-Duplex Converter
- Install a Versatile Interface Module in a 5520 Series Switch
- Installing a V300 Virtual Port Extender
- Replacing AC Power Supplies
- Replacing Fan Modules
- Monitoring the Device
- Technical Specifications
- ExtremeSwitching 5520 Series Technical Specifications
- V300 Virtual Port Extender Specifications
- V400 Virtual Port Extender Technical Specifications
- Half-Duplex to Full-Duplex Converter Technical Specifications
- 350 W AC Power Supplies Technical Specifications
- 715 W AC Power Supplies Technical Specifications
- 1100 W AC Power Supplies Technical Specifications
- 2000 W AC Power Supply Technical Specifications
- Power Cord Requirements for AC-Powered Switches and AC Power Supplies
- Console Connector Pinouts
- Safety and Regulatory Information
- Considerations Before Installing
- General Safety Precautions
- Maintenance Safety
- Fiber Optic Ports and Optical Safety
- Cable Routing for LAN Systems
- Installing Power Supply Units and Connecting Power
- Selecting Power Supply Cords
- Battery Notice
- Battery Warning - Taiwan
- EMC Warnings
- Japan (VCCI Class A)
- Korea EMC Statement
- Glossary
- Index
Table 57: Power Specifications
Minimum
3
Heat
Dissipation
(BTU/hr)
Minimum
3
Power
Consumption
(Watts)
Maximum
3
Heat
Dissipation
(BTU/hr)
Maximum
3
Power
Consumption
(Watts)
V300-8P-2X 25.9 7.6W 118.2 214.6W
V300-8T-2X 11.6 3.3W 23.8 7.0W
V300-8P-2T-W 24.57 7.2W 82.1 129.1W
V300HT-8P-2X 25.8 7.6W 113.7 213.3W
V300HT-8T-2X 16.6 4.9W 7.4 25.2W
Standards and Environmental Data
Table 58: Safety Standards
North American Safety of ITE UL 60950-1 2nd Ed., A2:2014, Listed Device (US)
CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety of ITE EN 60950-1:2006 +A11+A1+A12+A2
EN 60825-1:2007 (Lasers Safety)
IEC 60950-1:2005 2nd+A1:2009+A2:2013
2014/35/EU Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1:2005 2nd Ed. + National
Dierences
AS/NZX 60950-1 (Australia /New Zealand)
Table 59: Environmental Data
Operating conditions Temperature: 0°C to 60°C (32°F to 140°F) for V300 8P-2T-W and
V300-8P/8T-2X models
Temperature: -40°C to 70°C (-40°F to 158°F) for V300HT-8P/8T-2X
models
Storage and transportation temperature: -40°C to 70°C (-40°F to
158°F)
Humidity: 5% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
2
Minimum is defined as idle, with no ports linked. Maximum is defined as fans high, all ports 100% trac.