Installing the Virtual Services Platform 4450GTX-HT-PWR+ 9035362 Rev.
© 2017-2018, Extreme Networks, Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that the information in this document is complete and accurate at the time of printing, Extreme Networks, Inc. assumes no liability for any errors. Extreme Networks, Inc. reserves the right to make changes and corrections to the information in this document without the obligation to notify any person or organization of such changes.
including any code and software unless expressly authorized by Extreme Networks. Unauthorized reproduction, transmission, dissemination, storage, and or use without the express written consent of Extreme Networks can be a criminal, as well as a civil offense under the applicable law. Virtualization The following applies if the product is deployed on a virtual machine. Each product has its own ordering code and license types.
Contents Chapter 1: Preface.................................................................................................................... 6 Purpose.................................................................................................................................. 6 Training.................................................................................................................................. 6 Providing Feedback to Us.............................................................
Contents Switch LED state indicators.............................................................................................. 33 Port LED state indicators................................................................................................. 34 Viewing hardware information................................................................................................. 36 Chapter 6: Translations of safety messages........................................................................
Chapter 1: Preface Purpose This guide provides information and instructions to install a Extreme Networks Virtual Services Platform 4450GTX-HT-PWR+ switch. Training Ongoing product training is available. For more information or to register, you can access the Web site at www.extremenetworks.com/education/.
Extreme Networks Documentation - Email: support@extremenetworks.com. To expedite your message, enter the product name or model number in the subject line. • GTAC Knowledge – Get on-demand and tested resolutions from the GTAC Knowledgebase, or create a help case if you need more guidance. • The Hub – A forum for Extreme customers to connect with one another, get questions answered, share ideas and feedback, and get problems solved.
Preface About this task You can modify your product selections at any time. Procedure 1. In an Internet browser, go to http://www.extremenetworks.com/support/service-notificationform/ . 2. Type your first and last name. 3. Type the name of your company. 4. Type your email address. 5. Type your job title. 6. Select the industry in which your company operates. 7. Confirm your geographic information is correct. 8. Select the products for which you would like to receive notifications. 9. Click Submit.
Chapter 2: New in this document There are no feature-related changes for this release in Installing the Virtual Services Platform 4450GTX-HT-PWR+.
Chapter 3: Hardware models The following table describes the VSP 4450GTX-HT-PWR+ hardware. Table 1: Hardware VSP 4000 model Description Part number VSP 4450GTX-HT-PWR+ • 48 10/100/1000 Mbps RJ45 ports with 802.3at PoE+ EC4400A03-E6 • 2 Combo 100/1000 Mbps SFP ports • 2 1/10 Gbps SFP+ ports with MACsec capable PHY • Base Software License • one (of two) field replaceable 1000W PSUs supplied with the chassis Power cords must be ordered separately. Ensure you order the correct power code for your region.
Platform power supplies Platform power supplies The Virtual Services Platform 4450GTX-HT-PWR+ model supports two field-replaceable AC power supplies. One power supply is supplied with the chassis. You can install a redundant power supply to support load sharing or to provide power redundancy. The following table describes the Virtual Services Platform 4000 compatible AC power supplies and their part numbers (order codes). All the power supplies are EUED RoHS 5/6 compliant.
Hardware models AA0020072-E6 Power cord 2.5 m IEC C15 to CEE 7/7 European Union AA0020073-E6 Power cord 2.5 m IEC C15 to JIS 8303 Japan AA0020074-E6 POWER CORD 2.0M IEC C15 TO NEMA 5-15P United States/Canada AA0020075-E6 Power cord 2.5 m IEC C15 to AS 3112 Australia AA0020097-E6 Power cord 2.5 m IEC C15 to SANS 164-1 PLUG South Africa AA0020100-E6 Power cord 2.5 m IEC C15 to NBR 14136 Brazil AA0020103-E6 Power cord 2.5 m IEC C15 to SEV 1011 Switzerland AA0020105-E6 Power cord 2.
Supported optical devices For more information about SFP and SFP+ transceivers, including technical specifications and installation instructions, see Installing Transceivers and Optical components on VSP Operating System Software, NN47227-301. Compatible transceivers Important: Extreme Networks recommends using SFP and SFP+ transceivers as they have been through extensive qualification and testing. Extreme Networks will not be responsible for issues related to third party transceivers.
Chapter 4: Preinstallation checklist Before you install the VSP 4450GTX-HT-PWR+, make sure that you complete the tasks in the preinstallation checklist. No. Task Description 1. Review the technical specification for the switch. Make sure that the area where you install the switch and where it will operate meet the requirements. For the physical, electrical, and environmental specifications, see Technical specifications on page 19. 2. Verify the power supply unit (PSU) specifications.
No. Task Description in the area. The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode.
Chapter 5: Installing the VSP 4450GTX-HTPWR+ Installation checklist Use this checklist to install the VSP 4450GTX-HT-PWR+. No. Task Description 1. Install the VSP 4450GTX-HT-PWR+. You can install the switch in two ways: • Installing the Virtual Services Platform 4000 on a table or shelf on page 21 • Installing the Virtual Services Platform 4000 in an equipment rack on page 22 2. Install the primary or redundant power supply.
Electrostatic discharge 2. 2 Combo 100/1000 Mbps SFP ports supporting fiber or copper connection 3. 2 1/10 Gbps SFP+ ports for fiber or copper connection Figure 1: VSP 4450GTX-HT-PWR+ 1. USB 2.0 port Note: The VSP 4450GTX-HT-PWR+ model does not require a USB device in the USB port for normal operation. The USB port can be used for file transfer of configs and logs using a USB drive. 2. Switch LEDs 3. 10/100/1000 Mbps PoE+ ports (LEDs above ports) 4. Combo 100/1000 Mbps SFP slots.
Installing the VSP 4450GTX-HT-PWR+ • Ensure that you properly ground work surfaces and equipment racks for protection against electrostatic discharge. You must connect the common point to the building ground wire. In a properly wired building, the nearest reliable ground is typically at the electrical outlet. • Avoid contact between equipment and clothing. The wrist or ankle strap protects only the equipment from ESD voltages on the body; ESD voltages on clothing can still cause damage.
Technical specifications Technical specifications The following table provides the technical specifications for the individual switches in this series. Ensure that the area where you install the switch and where it operates meets these requirements. Warning: To avoid bodily injury from hazardous electrical shock and current, never remove the top of the device. No user-serviceable components are inside. Table 5: Physical specifications Specifications 4450GTX-HT-PWR+ Height 8.8 cm. – 2RU Width 44 cm.
Installing the VSP 4450GTX-HT-PWR+ Environmental requirement Virtual Services Platform 4000 models Miscellaneous Operating Considerations • No heat sources such as hot air vents or direct sunlight near the switch. • No sources of severe electromagnetic interference near the switch. • No excessive dust in the environment. • An adequate power source is within 6 feet (1.83 meters) of the switch. One 15-amp circuit is required for each power supply. • At least 2 inches (5.
Installing the Virtual Services Platform 4000 on a table or shelf 3. Rubber footpads 4. Documentation that includes the following: a. Locating the latest software and product release notes for Virtual Services Platform 4000 Series b. Virtual Services Platform 4000 Series Regulatory Guide c. Virtual Services Platform 4450GTX-HT-PWR+ Quick Install Guide d. The China RoHS paper 5. Note: Power cords must be ordered separately. Ensure you order the correct power code for your region.
Installing the VSP 4450GTX-HT-PWR+ Installing the Virtual Services Platform 4000 in an equipment rack To install the VSP 4000 switch in an equipment rack, perform this procedure. Prerequisites for installing the VSP 4000 in an equipment rack: • Ensure that you have a space of 1.75 inches (4.45 centimeters) in height for each switch in an EIA or IEC-standard 19-inch (48.2-centimeter) equipment rack. • The rack is bolted to the floor and braced if necessary.
Installing the Virtual Services Platform 4000 in an equipment rack 2. Slide the switch into the rack as illustrated. 3. Insert and tighten the rack-mount screws.
Installing the VSP 4450GTX-HT-PWR+ Cable requirements for the Virtual Services Platform 4000 The following table describes the cables required for the VSP 4000 switch. Table 7: Switch cable requirements Required Cable Description 10/100/1000BASE-T Ports The interconnect cabling must conform to the Cat5e, Cat6, or Cat6e specification of the Commercial Building Telecommunications Cabling Standard, ANSI/TIA/EIA 568-B fitted with an RJ45 Module jack.
Installation and removal of Small Form Factor Pluggable (SFP) transceivers Installing SFP transceivers Install SFP transceivers by performing this procedure. 1. Remove the transceiver from the protective packaging. 2. Verify that the transceiver is the correct model for the network configuration. 3. Grasp the transceiver between your thumb and forefinger. 4. Insert the transceiver into the proper module on the switch.
Installing the VSP 4450GTX-HT-PWR+ RJ45 connector pin assignments The following section describes the connector pin assignments for the RJ45 connectors in the Virtual Services Platform 4000 Series switches. Console port pin assignments The following table describes the console port pin assignments in the VSP 4000. Important: VSP 4000 supports only CLI Quickstart use on the console port.
Installing the Virtual Services Platform 4000 power supply Installing the Virtual Services Platform 4000 power supply You must install at least one power supply before using the switch. VSP 4000 models support two field replaceable external power supplies. If supported, you can install an optional second power supply for redundancy, load sharing, or to provide additional PoE+ power budget. About this task Perform the following procedure to install an external power supply into your switch.
Installing the VSP 4450GTX-HT-PWR+ 1000W AC power supply VSP 4450GTX-HT-PWR+ supports dual 54V 1000W Power over Ethernet Plus (PoE+) AC power supplies. Important: Ensure that you use only 1000W power supplies (both primary and secondary) on VSP 4450GTX-HT-PWR+ models. Figure 3: 1000W AC power supply Connector The 1000W AC power supply uses an IEC 60320 C16 AC power cord connector. The AC power cord is in close proximity to the hot air exhaust, and supports high operating temperatures.
Connect AC power Table 11: VSP 4450GTX-HT-PWR+ model with 1 PSU 0°C to 50°C 50°C to 70°C 48 ports 23 ports PoE+ support on 26 ports 13 ports PoE support on Table 12: VSP 4450GTX-HT-PWR+ model with 2 PSUs 0°C to 50°C 50°C to 70°C 48 ports 48 ports PoE+ support on 48 ports 26 ports PoE support on • VSP 4450GTX-HT-PWR+ can support 802.3af 17.8W or 32.4W on each port with one power supply installed. You can add a second power supply for redundancy.
Installing the VSP 4450GTX-HT-PWR+ Power cord specifications To connect AC power to the switch, you need an appropriate AC power cord as described in the following table, also see the following table for plug specifications.
Connect AC power Important: The VSP 4000 series has no AC power switch. When you connect the power cord to a suitable, energized AC power outlet, the switch powers up immediately. Figure 5: Connecting AC power to the front panel Warning: Disconnecting the AC power cord is the only way to turn off AC power to the VSP 4000. Always connect the AC power cord in a quickly and safely accessible location in case of an emergency.
Installing the VSP 4450GTX-HT-PWR+ CP1 [03/24/14 18:39:08.000] LifeCycle: INFO: All processes have stopped CP1 [03/24/14 18:39:08.000] LifeCycle: INFO: All applications shutdown, starting power down sequence INIT: Sending processes the TERM signal Stopping OpenBSD Secure Shell server: sshdno /usr/sbin/sshd found; none killed cat: can't open '/proc/mtd': No such file or directory cat: can't open '/proc/mtd': No such file or directory Stopping vsp...
LED state definitions Front panel LEDs The following diagram illustrates the components on the front panels of the VSP 4450GTX-HT-PWR + switch. For detailed explanations of the states indicated by each front panel LED type, see the following sections: • Switch LED state indicators on page 33 • Port LED state indicators on page 34 Figure 6: VSP 4450GTX-HT-PWR+ 1. USB 2.0 port 2. Switch LEDs 3. 10/100/1000 Mbps RJ45 ports with PoE+ (LEDs above ports) 4. 100/1000 Mbps Combo SFP slots.
Installing the VSP 4450GTX-HT-PWR+ Label Status Color and Status Description Green (blinking) System is in reset. Off The switch is not receiving power and not operating. Green (solid) • During start-up: The power-on self-test (POST) is complete and the switch is operating normally. • After start-up: The switch is running the agent code successfully. RPS Green (blinking) The switch is loading the agent software code.
LED state definitions Table 16: RJ45 Port LED state indicators Label Color and Status Description Speed/PoE+ Green, Blink The port is set to operate at 1000 Mbps with PoE. Green, Steady The port is set to operate at 1000 Mbps without PoE+. Amber, Blink The port is set to operate at 100 Mbps with PoE+. Amber, Steady The port is set to operate at 100 Mbps without PoE+. Amber, Green Pulse The port is experiencing a PoE+ error.
Installing the VSP 4450GTX-HT-PWR+ Viewing hardware information About this task Perform the following procedure to view system status and technical information about the VSP 4450GTX-HT-PWR+ hardware components. You can view information about the switch (such as location), chassis (type, serial number, and base MAC address), temperature, power supplies, fans, cards, system errors, port locks, topology status, and message control information. Procedure 1. Log on to the switch to enter User EXEC mode. 2.
Viewing hardware information Fan Info : Description Tray 1 Fan 1 Tray 1 Fan 2 Tray 1 Fan 3 Tray 1 Fan 4 Tray 1 Fan 5 OperStatus up up up up up OperSpeed mediumSpeed mediumSpeed mediumSpeed mediumSpeed mediumSpeed AirflowDir left-right left-right left-right left-right left-right LED Info : LED#1 Label : PWR LED#1 Status : GreenSteady LED#2 Label : Status LED#2 Status : GreenSteady LED#3 Label : Rps LED#3 Status : Off LED#4 Label : Up LED#4 Status : UnSupported LED#5 Label : Down LED#5 Status : UnSupport
Installing the VSP 4450GTX-HT-PWR+ Variable Value fan Displays information about installed cooling ports. led Displays LED information in detail. power Displays information about installed power supplies. temperature Displays temperature information. uboot Displays uboot details.
Chapter 6: Translations of safety messages Caution: When you mount this device in a rack, do not stack units directly on top of one another. You must secure each unit to the rack with appropriate mounting brackets. Mounting brackets cannot support multiple units. Important: Achtung: Wenn diese Einheit in einem Rack montiert wird, muß ein gewisser Abstand zur nächsten Einheit gelassen werden. Jede Einheit muß mit geeignetem Befestigungsmaterial gesichert werden.
Translations of safety messages Caution: If you are not installing a module in the slot, be sure to keep the metal cover plate in place over the slot. Removing the cover plate impedes airflow and proper cooling of the unit. Important: Achtung: Wenn Sie kein Modul im Schacht verwenden, muß die Metallabdeckung über dem Schacht montiert sein. Eine Entfernung der Abdeckung führt zu einer Verschlechterung der Luftzirkulation und damit zu einer nicht ausreichenden Kühlung der Einheit.
Warning: Disconnecting the AC power cord is the only way to turn off AC power to this device. Always connect the AC power cord in a quickly and safely accessible location in case of an emergency. Important: Warnung: Das Gerät kann nur durch Ziehen des Netzsteckers ausgeschaltet werden. Schließen Sie das Netzkabel an einer Steckdose an, die in Notfällen schnell und sicher zugänglich ist.
Translations of safety messages Verwenden Sie nur Netzkabel mit Schutzerdung. Ohne ordnungsgemäße Schutzerdung besteht für Personen, die den Switch berühren, die Gefahr eines elektrischen Schlages. Eine nichtvorhandene Schutzerdung kann zu sehr starken Abstrahlungen führen. Danger: N'utilisez que des cordons d'alimentation équipés de trajet de mise à la terre. Sans mise à la terre adaptée, vous risquez de recevoir une décharge électrique en touchant le commutateur.
Important: 警告: 锂锂池不支持锂锂更锂, 只有授锂人锂才能锂行拆卸和更锂。 如果您需要更锂锂池,锂锂系 Extreme Networks 技锂支持部锂锂求帮助。 Important: Advertencia: La batería de litio no puede sustituirse en campo. La extracción y sustitución debe ser realizada exclusivamente por personal autorizado. Comuníquese con el Soporte técnico de Extreme Networks si necesita asistencia para cambiar la batería. Important: Aviso: A bateria de lítio não é substituível em campo. Só deve ser removida e substituída por pessoal autorizado.