© 2015, Avaya Inc. All Rights Reserved. Notice While reasonable efforts have been made to ensure that the information in this document is complete and accurate at the time of printing, Avaya assumes no liability for any errors. Avaya reserves the right to make changes and corrections to the information in this document without the obligation to notify any person or organization of such changes.
result in substantial additional charges for your telecommunications services. Avaya Toll Fraud intervention If You suspect that You are being victimized by Toll Fraud and You need technical assistance or support, call Technical Service Center Toll Fraud Intervention Hotline at +1-800-643-2353 for the United States and Canada. For additional support telephone numbers, see the Avaya Support website: http://support.avaya.com or such successor site as designated by Avaya.
Contents Chapter 1: Introduction............................................................................................................ 5 Purpose.................................................................................................................................. 5 Related resources................................................................................................................... 5 Documentation.................................................................................
Chapter 1: Introduction Purpose This guide provides information and instructions to install an Avaya Virtual Services Platform 7200 Series (VSP 7200 Series) switch. Related resources Documentation See the Documentation Reference for Avaya Virtual Services Platform 7200 Series and 8000 Series, NN47227-100 for a list of the documentation for this product. Training Ongoing product training is available. For more information or to register, you can access the Web site at http://avaya-learning.com/.
Introduction - In Search, type the product name. On the Search Results page, select Video in the Content Type column on the left. • To find the Avaya Mentor videos on YouTube, go to www.youtube.com/AvayaMentor and perform one of the following actions: - Enter a key word or key words in the Search Channel to search for a specific product or topic. - Scroll down Playlists, and click the name of a topic to see the available list of videos posted on the website. Note: Videos are not available for all products.
Related resources 6. Click OK. 7. In the PRODUCT NOTIFICATIONS area, click Add More Products. 8. Scroll through the list, and then select the product name. 9. Select a release version. 10. Select the check box next to the required documentation types. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Introduction 11. Click Submit. Support Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation, product notices, and knowledge articles. You can also search for release notes, downloads, and resolutions to issues. Use the online service request system to create a service request. Chat with live agents to get answers to questions, or request an agent to connect you to a support team if an issue requires additional expertise.
Support 3. In the Search dialog box, select the option In the index named .pdx. 4. Enter a search word or phrase. 5. Select any of the following to narrow your search: • Whole Words Only • Case-Sensitive • Include Bookmarks • Include Comments 6. Click Search. The search results show the number of documents and instances found. You can sort the search results by Relevance Ranking, Date Modified, Filename, or Location. The default is Relevance Ranking.
Chapter 2: New in this release The Avaya Virtual Services Platform 7200 Series is new for VOSS 4.2.1 release, so all the content in this document is new in this release. See Release Notes for VSP Operating System Software, NN47227-401 for a full list of VOSS 4.2.1 release features. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Chapter 3: Hardware models Hardware models for VSP 7200 Series This section lists the VSP 7200 Series hardware. VSP 7200 hardware Table 1: VSP 7200 Hardware VSP 7200 Series Description Part numbers VSP 7254XSQ - fiber switch • 48 1/10 GbE SFP/SFP+ ports Model EC7200x1B-E6 ships with back-to-front fan modules and one back-to-front 460 W AC PSU.
Hardware models VSP 7200 Series Description • one USB port Part numbers • Base Software License • three field-replaceable fan modules VSP 7254XTQ - copper switch Model EC720002F-E6 ships with one front-to-back 800 W DC PSU. Includes all of the above components except the SFP+ ports are replaced with forty eight 100 Mbps/1 GbE/10 GbE RJ-45 ports.
Hardware models for VSP 7200 Series VSP 7200 Series Description Part numbers *Note: The character (x) in the order number indicates the power cord code. Replace the “x” with the proper letter to indicate desired product nationalization. See the following for details: “A”: No power cord included. “B”: Includes European “Schuko” power cord common in Austria, Belgium, Finland, France, Germany, The Netherlands, Norway, and Sweden. “C”: Includes power cord commonly used in the United Kingdom and Ireland.
Hardware models operate and the port link will come up. The switch logs the device as an unsupported or unknown device. • The VSP 7200 Series operates in strict mode for SFP+ and QSFP+ transceivers, which means that the switch will not bring the port up operationally when using non-Avaya SFP+ or QSFP+ transceivers.
Hardware models for VSP 7200 Series • Avaya recommends enabling auto-negotiation to ensure proper operation at 100M speeds on VSP 7254XTQ: - Link instability will be seen if both ends are set to 100M auto-negotiation disabled and a straight through cable is used. - If Link instability is seen when using a cross-over cable, a port disable or enable can fix the issue.
Chapter 4: Preinstallation checklist Preinstallation checklist Before you install the Avaya Virtual Services Platform 7200 Series, make sure that you complete the tasks in the preinstallation checklist. Important: Make sure the air flow direction of your power supplies and fan modules match the same direction (either front-to-back or back-to-front). No. Task Description 1. Review the technical specification for the switch.
Preinstallation checklist No. Task Description 6. Verify the contents of the shipped package. See Package contents on page 23 for a description of the components that are provided with the switch. If any components are missing, contact Avaya support at http:// support.avaya.com/. 7. Make sure that the power cord has the correct country-specific termination. 8. Prepare the rack. Ensure that there is enough rack space to accommodate a 1RU switch (4.45 cm).
Chapter 5: Installing the Avaya Virtual Services Platform 7200 Series This section provides the information and procedures to install the Avaya Virtual Services Platform 7200 Series. Installation checklist Use this checklist to install the Avaya Virtual Services Platform 7200 Series. No. Task Description 1. Mount the Avaya Virtual Services Platform 7200 Series in the equipment rack. See Installing the switch in an equipment rack on page 40.
Installation fundamentals Installation fundamentals The VSP 7200 Series has two models: VSP 7254XSQ (fiber) and VSP 7254XTQ (copper). The VSP 7254XSQ consists of forty eight 1/10 GbE SFP/SFP+ ports. The VSP 7254XTQ consists of forty eight 100 Mbps/1 GbE/10 GbE RJ-45 ports.
Installing the Avaya Virtual Services Platform 7200 Series Figure 2: VSP 7200 — Rear view 1. Console port 2. Management port — The LEDs are on the bottom of the port. For more information, see Management port LEDs on page 39. Electrostatic discharge This section provides information and procedures to prevent electrostatic discharge during installation.
Technical specifications • Avoid contact between equipment and clothing. The wrist or ankle strap protects only the equipment from ESD voltages on the body; ESD voltages on clothing can still cause damage. • Avoid touching any connector pins. • Do not remove the wrist or ankle strap until the installation is complete.
Installing the Avaya Virtual Services Platform 7200 Series Warning: To avoid bodily injury from hazardous electrical shock and current, never remove the top of the device. No user-serviceable components are inside. Table 2: Physical Specifications Height 1.75 in. (4.4 cm) - 1U Width 17.5 in. (444.5 mm) - 19” rack mountable Depth 17.2 in. (43.6 cm) Weight of VSP 7254XSQ 16 lb (7.25 kg) Weight of VSP 7254XTQ 18.85 lb (8.55 kg) Weight of 460W AC power supply unit 1.95 lb (.
Package contents • An adequate power source is within 6 feet (1.83 meters) of the switch. One 15-amp circuit is required for each power supply. • At least 2 inches (5.08 centimeters) of clearance on the front and back of the switch for ventilation. • Cables should be dressed to prevent blocking air flow. Package contents The following describes the components that are provided with each switch. If any components are missing, contact the switch vendor. 1.
Installing the Avaya Virtual Services Platform 7200 Series • If you install a second power supply, neither one acts as a primary power supply. The two power supplies load share equally. Important: Avaya does not support installing a combination of AC-input and DC-input power supplies in the same chassis. To install an AC power supply, see Installing an AC power supply on page 24. To install a DC power supply, see Installing a DC power supply on page 29.
Installing a power supply • EC7205C0F-E6 — 800W AC POWER SUPPLY FRONT2BACK COOLING (UK PC) • EC7205D0B-E6 — 800W AC POWER SUPPLY BACK2FRONT COOLING (JP PC) • EC7205D0F-E6 — 800W AC POWER SUPPLY FRONT2BACK COOLING (JP PC) • EC7205E0B-E6 — 800W AC POWER SUPPLY BACK2FRONT COOLING (NA PC) • EC7205E0F-E6 — 800W AC POWER SUPPLY FRONT2BACK COOLING (NA PC) • EC7205F0B-E6 — 800W AC POWER SUPPLY BACK2FRONT COOLING (ANZ PC) • EC7205F0F-E6 — 800W AC POWER SUPPLY FRONT2BACK COOLING (ANZ PC) Before you begin Remove the
Installing the Avaya Virtual Services Platform 7200 Series 2. Slide the power supply into the slot. 3. Verify that the power supply is fully seated in the slot. The spring latch should engage and return to its original position. Note: The chassis design prevents an incorrect installation of a power supply. If you insert a power supply upside down, it will not fully insert. 4.
Installing a power supply The VSP 7254XTQ comes with an 800 W AC power supply and you can install a secondary power supply for redundancy. Important: You must have either a power supply or a power supply cover in each bay to ensure proper ventilation. Leaving a power supply bay unpopulated or uncovered impairs the ability of the fans to cool the chassis. Figure 4: AC power supply The AC power supplies use an IEC 60320 C16 AC power cord connector.
Installing the Avaya Virtual Services Platform 7200 Series 7254XSQ Inrush Current: 55 A maximum Turn on Condition: 5–400 ms delay after application of AC power Important: The output rise time, from 10 to 90 percent, is 70 ms maximum and monotonic under all defined input and output conditions. Efficiency: 85 percent minimum Table 5: 800 W AC power specifications 7254XTQ Input Current: 9.9–4.
Installing a power supply Country and Plug Specification Specifications United Kingdom: • 240VAC • BS1363 male plug with fuse • 50 Hz • Harmonized cord • Single phase Australia: • 240VAC • AS3112-1981 male plug • 50 Hz Typical Plug • Single phase Danger: Using power cords with a proper grounding path Use only power cords that have a grounding path. Without a proper ground, a person who touches the switch is in danger of receiving an electrical shock.
Installing the Avaya Virtual Services Platform 7200 Series Procedure 1. If there is a power supply cover, remove it and save for possible future use. To remove the cover, push the tab on the spring latch to the left and pull on the extraction handle. Important: If you only have one power supply installed, the other slot must be covered to ensure proper ventilation. If a power supply fails, replace it as soon as you can but leave it in place until you do.
Installing a power supply Note: The chassis design prevents an incorrect installation of a power supply. If you insert a power supply upside down, it will not fully insert. Important: The VSP 7200 Series does not have a power switch. When you connect the DC power source to the DC power supply wiring assembly and then plug the DC power supply wiring assembly into the DC power supply, the switch powers up immediately.
Installing the Avaya Virtual Services Platform 7200 Series c. Use a screwdriver to terminate the cables to the DC power supply wiring assembly. d. Connect the DC power supply wiring assembly to the DC power supply and screw it in to secure the connection. 5. Check the LED on the top right side of the power supply. If it is off, the power supply is not operating. If it is green, the power supply is operating normally. The following table describes all the LED states.
Installing a power supply DC power supply specifications The VSP 7200 Series comes with one 800 W DC power supply and you can install a secondary power supply for redundancy. Important: You must have either a power supply or a power supply cover in each bay to ensure proper ventilation. Leaving a power supply bay unpopulated or uncovered impairs the ability of the fans to cool the chassis.
Installing the Avaya Virtual Services Platform 7200 Series Removing a power supply You can hot swap power supplies while the switch is operational. Procedure 1. Disconnect the power cord from the power supply. 2. Lift up the power supply handle so you can grasp it. 3. Push the spring latch to the left and use the power supply handle to pull the power supply out of the chassis. 4. If you are replacing the power supply, see Installing an AC power supply on page 24 or Installing a DC power supply on page 29.
Installing a fan module Procedure 1. Check the Fan LED on the front of the chassis. Solid green indicates that all fan modules are operating normally. Blinking amber indicates that a fan module failed. 2. Enter the following command to determine which fan module failed. show sys-info fan This command shows the status of each fan module: up, down, or Not Present when a fan is removed. 3.
Installing the Avaya Virtual Services Platform 7200 Series The Fan IDs are assigned from left to right as you face the back of the chassis. For the first fan module on the far left, the Fan IDs are 1 and 2, the next fan module has Fan IDs 3 and 4, and the fan module on the far right has Fan IDs 5 and 6.
LED state definitions Important: In addition to the fan modules, each power supply also has a fan. The power supply stops working if a power supply fan fails, but there is no LED or software warning that indicates this failure. Try to recover the power supply fan by resetting the switch. If the fan does not recover, then replace the faulty power supply. Table 9: Switch LED state indicators Label Color and Status Description PWR Off The switch is not receiving power and not operating.
Installing the Avaya Virtual Services Platform 7200 Series Table 10: 100 Mbps/1 Gbps/10 Gbps port LED state indicators Label Color and Status Description Link/Act Off There is no transceiver present and the port is administratively enabled. Amber (steady) The port has a link in 100 Mbps mode. Amber (blinking) The port has a link and data activity in 100 Mbps mode. Green (steady) The port has a link in 1 Gbps mode. Green (blinking) The port has a link and data activity in 1 Gbps mode.
LED state definitions Each 40 Gb QSFP+ port can be channelized into 4 x 10 Gb ports. To support channelization, each QSFP+ port has four status LEDs under the port. When the QSFP+ port is not channelized, only the LED on the left side of the port is used. Table 12: SFP/SFP+ port LED state indicators Label Color and Status Description Link/Act Off There is no transceiver present and the port is administratively enabled. Amber (steady) The port is actively transmitting, but there is no link.
Installing the Avaya Virtual Services Platform 7200 Series Enterprise Device Manager (EDM) representation of physical LED status EDM displays the same LEDs that you see on the physical device. Note: LED blinking in EDM is representative of, but not identical to, the actual LED blinking rates on the switch. For more information about the LEDs and a description of the blinking rates, see the preceding LED sections.
Installing the switch in an equipment rack Using the optional slide rack mount kit The Universal Slide Rack Mount Kit is adjustable so that you can install your switch in equipment racks of different sizes. Use the following procedures to install your switch in equipment racks with a depth from 300mm to 900mm. This kit is a separately ordered item (Part # EC8011002).
Installing the Avaya Virtual Services Platform 7200 Series 2. Use the following steps to detach the chassis rail from the slide’s rack rail: a. Pull the inner chassis rail and slide it out as far as you can. b. Slide the white release lock in the direction of the arrow stamped on the lock. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack 3. Lift the locking mechanism on the rack rail to slide the outer section back into the main section. 4. Use the following steps to attach the chassis rail to the chassis: a. Orient the chassis rail with the blue release lock towards the front and position the rail over the standoffs on the chassis. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the Avaya Virtual Services Platform 7200 Series b. Slide the chassis rail to the rear until the rail locks into the standoffs. c. Make sure the safety tab locks into place. 5. Use the following steps to secure the rack rails to the frame: a. Orient the rack rail so that the end with the black latch is facing front. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack b. Adjust the length of the rack rail so it fits the rack depth by loosening the two screws on the rack rail, adjusting the length, and then tightening the screws. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the Avaya Virtual Services Platform 7200 Series c. Push the end of the front bracket assembly so it opens up. d. Insert the bracket pins into the desired holes in the frame. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack e. Close the bracket assembly so that it wraps around the frame and locks into place. f. Repeat the above steps on the rear bracket. g. Repeat these steps for the rack rail on the other side of the frame. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the Avaya Virtual Services Platform 7200 Series 6. Use the following steps to install the switch in the equipment rack to complete the installation: a. Insert the chassis rails on the switch into the rack rails on the frame. b. Pull the blue locks on the chassis rails towards the front and slide the switch into the frame. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack Note: After you install the switch in a rack, slide it out until the lock (shown above) engages. To slide the switch back into the rack, push the blue locks on the chassis rails towards the back and slide the switch into the frame. 7. Connect power and network connections to the switch. Installing slides in a 600mm-900mm equipment rack Use the following procedure to install your switch in an equipment rack with a depth between 600mm and 900mm. Procedure 1.
Installing the Avaya Virtual Services Platform 7200 Series October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack 6. Use the bag with 10 countersink screws and following steps to attach the supporting plates to the rack rails: a. Push the release lock up and slide the middle rail out as far as possible. b. Orient the supporting plate over the holes in the rack rail. c. Install the first two screws on one end. d. Lift the locking mechanism and slowly slide the rail back into the main assembly.
Installing the Avaya Virtual Services Platform 7200 Series 7. Insert the long rack rail bracket into the supporting plate. 8. Use the following steps to secure the rack rails to the frame: a. Orient the rack rail so that the end with the black latch is facing front. b. Push the end of the front bracket assembly so it opens up. c. Insert the bracket pins into the desired holes in the frame. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Installing the switch in an equipment rack d. Close the bracket assembly so that it wraps around the frame and locks into place. e. Repeat the above steps on the rear bracket. f. Repeat these steps for the rack rail on the other side of the frame. 9. Install the switch in the equipment rack to complete the installation. (See Step 6 of the 300mm-600mm instructions.) a. Insert the chassis rails on the switch into the rack rails on the frame. b.
Installing the Avaya Virtual Services Platform 7200 Series Important notice about rack safety One prerequisite to installing the switch in an equipment rack is to bolt the equipment rack to the floor. Warning: If you pull the chassis all the way out on the slide rails, there is a danger of the rack tipping over. This can happen if there are no other devices installed in your equipment rack and the rack is not bolted to the floor.
Installing the switch in an equipment rack pulls the chassis out of the rack. Using the supplied brackets This procedure describes how to install the switch in an equipment rack using the supplied brackets. The brackets that come with the chassis are for mounting the unit in a standard 19–inch rack. Avaya recommends that you mount a tray into the rack and set the chassis upon the tray.
Installing the Avaya Virtual Services Platform 7200 Series 2. Attach a bracket to each side of the switch using a #2 Phillips screwdriver as illustrated below. 3. Slide the switch onto a shelf or tray in the rack. 4. Insert and tighten the rack-mount screws. 5. Verify that the switch is securely fastened to the rack. 6. Connect power and network connections to the switch. October 2015 Installing the Avaya VSP 7200 Series Comments on this document? infodev@avaya.
Cable requirements for the VSP 7200 Cable requirements for the VSP 7200 The following table describes the cables required for an Avaya Virtual Services Platform 7200 Seriesswitch. Table 14: Switch cable requirements Required Cable Description 10/100/1000Base TX Ports The interconnect cabling must conform to the Cat5e, Cat6, or Cat6e specification of the Commercial Building Telecommunications Cabling Standard, ANSI/TIA/EIA 568-B fitted with an RJ-45 Module jack.
Installing the Avaya Virtual Services Platform 7200 Series Removing transceivers Remove transceivers by performing this procedure. 1. Disconnect the network fiber cable from the transceiver. 2. Use the locking mechanism on the transceiver to release it. The locking mechanism varies from model to model as illustrated below. 3. Slide the transceiver from the port. 4.
40GBASE-QSFP+ ports Connector Pin Number Signal 6 Receive data (RXD) — mandatory 7 Data set ready (DSR) — optional 8 Clear to send (CTS) — optional, can swap or link with pin 1 40GBASE-QSFP+ ports When a 40 Gigabit port is channelized, only use break out cables (DAC or Fiber) in it. Otherwise, the link behavior can be unpredictable because it can result in mismatched link status between link partners, which can further lead to network issues.
Chapter 6: Translations of safety messages Caution: When you mount this device in a rack, do not stack units directly on top of one another. You must secure each unit to the rack with appropriate mounting brackets. Mounting brackets cannot support multiple units. Important: Achtung: Wenn diese Einheit in einem Rack montiert wird, muß ein gewisser Abstand zur nächsten Einheit gelassen werden. Jede Einheit muß mit geeignetem Befestigungsmaterial gesichert werden.
Caution: If you are not installing a module in the slot, be sure to keep the metal cover plate in place over the slot. Removing the cover plate impedes airflow and proper cooling of the unit. Important: Achtung: Wenn Sie kein Modul im Schacht verwenden, muß die Metallabdeckung über dem Schacht montiert sein. Eine Entfernung der Abdeckung führt zu einer Verschlechterung der Luftzirkulation und damit zu einer nicht ausreichenden Kühlung der Einheit.
Translations of safety messages Warning: Disconnecting the AC power cord is the only way to turn off AC power to this device. Allow at least 30 seconds for the this device to fully power down before restoring power. Otherwise, this device might produce a core file during the reset leading to an extra delay during boot time. Always connect the AC power cord in a quickly and safely accessible location in case of an emergency.
Important: Vorsicht: Verwenden Sie nur Netzkabel mit Schutzerdung. Ohne ordnungsgemäße Schutzerdung besteht für Personen, die den Switch berühren, die Gefahr eines elektrischen Schlages. Eine nichtvorhandene Schutzerdung kann zu sehr starken Abstrahlungen führen. Danger: N'utilisez que des cordons d'alimentation équipés de trajet de mise à la terre. Sans mise à la terre adaptée, vous risquez de recevoir une décharge électrique en touchant le commutateur.