Quick Install Guide
2
Unpack the equipment and verify
package content
Confirm that you have the following tools and cables:
• Phillips #2 screwdriver
• RJ-45 console port cable
• ESD cable
Virtual Services Platform
7200 Series
Quick Install Guide
Avaya
1. Avaya Virtual Services Platform (VSP) 7200 Series switch
2. Rack-mounting hardware that includes:
a. Rack-mount brackets
b. Screws to attach brackets to the switch
c. Screws to attach the switch to the equipment rack
3. AC power cord or DC power supply wiring assembly
(Note: A power cord is not included with the “A” variants of
the switch.)
4. Documentation that includes this poster, regulatory information,
how to locate software, and how to locate Release Notes.
1
Before you start
This poster provides information and instructions to install
and commission a factory-supplied Avaya Virtual Services
Platform 7200 switch. You can download all documents
referenced in this guide at www.avaya.com/support.
Note: Observe ESD precautions when unpacking.
Optionally order a redundant PSU to provide redundancy and
load sharing. Make sure you order the correct power supplies
and fan trays so the air flow directions match (either front-to-
back or back-to-front).
VSP 7200 AC power specifications:
3
Verify power supply unit (PSU)
specifications
VSP 7200
model
Primary
PSU
Redundant PSU
(to be ordered if required)
VSP 7254XSQ -
fiber switch
Model EC7200x1B-E6
ships with one
back-to-front AC PSU.
Model EC7200x1F-E6
ships with one
front-to-back AC PSU.
460W AC
power supply
Replacement
order code:
EC7205?1B-E6
(back-to-front),
EC7205?1F-E6
(front-to-back)
460W AC power supply
Order code:
EC7205?1B-E6 (back-to-front),
EC7205?1F-E6 (front-to-back)
• “A”: No power cord included.
• “B”: Includes European
“Schuko” power cord common
in Austria, Belgium, Finland,
France, Germany,
The Netherlands, Norway,
and Sweden.
• “C”: Includes power cord
commonly used in the United
Kingdom and Ireland.
• “D”: Includes power cord
commonly used in Japan.
• “E”: Includes North American
power cord.
• “F”: Includes Australian
power cord.
VSP 7254XTQ -
copper switch
Model EC7200x2B-E6
ships with one
back-to-front AC PSU.
Model EC7200x2F-E6
ships with one
front-to-back AC PSU.
800W AC
power supply
Replacement
order code:
EC7205?0B-E6
(back-to-front),
EC7205?0F-E6
(front-to-back)
800W AC power supply
Order code:
EC7205?0B-E6 (back-to-front),
EC7205?0F-E6 (front-to-back)
Refer to the note above for
country code information.
The VSP 7200 supports two field-replaceable power supplies. One
power supply ships with the unit and you can optionally install a
second power supply for redundancy. If you install a second power
supply, the load is shared equally and neither one acts as a primary
power supply.
Use this procedure to install either the primary or redundant
power supply.
Notes:
• Avaya does not support installing a combination of AC-input and
DC-input power supplies in the same chassis.
• There are two power supply slots (PSU1 on the left and PSU2 on
the right). If you only have one power supply, you can install it in
either PSU1 or PSU2.
• The switch ships with filler panels covering the power supply
slots. If you’re not installing a second power supply, you must
leave one of the filler panels in place for proper cooling.
• You can hot swap power supplies while the switch is operational.
One power supply is required for continued switch operation.
1.
Remove the power supply cover by pushing the tab on the spring
latch to the left and pulling on the extraction handle. (Save the
filler panel for possible future use.)
2.
Insert the power supply into the slot.
3.
Verify that the power supply is fully seated in the slot (AC PSU
shown). The spring latch should engage and move back to its
original position.
4
Install power supply unit
Notes:
• The chassis design prevents an incorrect installation of a
power supply. If you insert a power supply upside down, it will
not fully insert.
• The spring latch design ensures that you remove the power
cord before removing a power supply from the chassis. If you
don’t remove the cord, you cannot move the latch to the left to
release the hooks from the chassis.
4. After you install a power supply, proceed with connecting either
the AC power cord or the DC power supply wiring assembly.
5. Check the LED on the power supply. If it is off, the power
supply is not operating. If it is green, the power supply is
operating normally.
The VSP 7200 comes with three 12-V fan trays for either
front-to-back or back-to-front air flow switch cooling. Make sure
you order the correct power supplies and fan trays so the air flow
directions match (either front-to-back or back-to-front).
Refer to the following part numbers to ensure that you install the
correct fan trays in your switch. Both the VSP 7254XSQ (fiber
switch) and the VSP 7254XTQ (copper switch) use the same fan
tray models:
• EC7200BTF-E6 — 12 V BACK2FRONT SPARE FAN TRAYS
(INC 3 FAN TRAY KITS)
• EC7200FTB-E6 — 12 V FRONT2BACK SPARE FAN TRAYS
(INC 3 FAN TRAY KITS)
Important:
All three fans must be installed at all times to ensure proper
ventilation. If a fan fails, leave it in place until you can replace it.
Leaving a fan bay unpopulated impairs the ability of the
remaining fans to cool the chassis.
1. Insert the fan trays into the chassis.
5
Install fan trays
There are two ways to install an Avaya VSP 7200 switch in an
equipment rack. Refer to one of the following sections:
• Mount the switch using the supplied bracket.
• Mount the switch using the optional slide rack mount kit.
Note: For more information, see Installing the Avaya
VSP 7200 Series, NN47228-302.
or
VSP 7200 DC power specifications:
VSP 7200
model
Primary
PSU
Redundant PSU
(to be ordered if required)
VSP 7254XSQ -
fiber switch
Model EC720001F-E6
ships with one
front-to-back DC PSU.
800W DC power
supply
Replacement
order code:
EC8005001-E6
(front-to-back)
800W DC power supply
Order code:
EC8005001-E6 (front-to-back)
VSP 7254XTQ -
copper switch
Model EC720002F-E6
ships with one
front-to-back DC PSU.
800W DC power
supply
Replacement
order code:
EC8005001-E6
(front-to-back)
800W DC power supply
Order code:
EC8005001-E6 (front-to-back)
6
Mount the VSP 7200 switch
2. Verify that each fan tray is fully seated in the chassis. The
spring latch should engage and return to its original position.
3. Check the Fan LED on the front of the chassis. Solid green
indicates that all fan trays are operating normally. Blinking
amber indicates that a fan tray failed.
4. If a fan tray fails, enter the following command to determine
which one failed.
show sys-info fan
This command shows the status of each fan tray: up, down, or
Not Present when a fan is removed.
5. Remove the fan tray that failed by pushing the tab on the
spring latch to the left and pulling on the fan’s extraction
handle. You can hot swap fan trays while the switch
is operational.
6. Enter the following command to check the temperature
sensors inside the switch.
show sys-info temperature
Link/Act
Link/Act
VSP 7254XTQ
PWR
Status
RPS
Fan
USB
1
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
2
6
Link/Act
1
5
Link/Act