Quick Reference Guide

Installing the ExtremeWiNG 802.11 a/ac+b/g/n
Indoor AP7632 Access Point
Overview of the AP7632
The AP7632 is an 802.11ac Wave 2 Access Point featuring dual 2x2:2 radios.
The all-metal design of the AP supports high operating temperatures, external
antennas, and flexible mounting options for wall mount, ceiling mount, beam
or T-bar. The AP can be powered by 802.3af or by using a 12VDC wall brick.
The AP7632 model has the following features:
Radios: 2 radios (2.4GHz and 5GHz); 1 IoT Radio (2.4 GHz)
•Console Port: RJ45
One RJ45, 10/100/1000 Ethernet Port (LAN1) with PoE
•LEDs: 4 (see Figure 2)
•One Reset button
Power: PoE 802.3af; 12VDC power in connector (see Table 1)
Antennas:
–Three external antennas (two dual band antennas and one IoT
antenna)
Three RSPMA mount style antenna connectors
External USB 2.0 port with features to support a locking module
•Safety Hangar provision
Temperature:
-20 to +55°C ambient temperature anywhere
-20 to +65°C ambient temperature near sea level
Enclosure: All metal - no plastic
In Figure 1, the top image indicates the top view of AP7632 and the bottom
one indicates the side view of AP7632.
Figure 1 Top and Side View of AP7632
Table 1 shows ways to power the AP7632.
Table 1 Powering the AP7632
Note: The AP7632 requires a minimum base firmware of WiNG 5.9.1.
1
2.4G/5G Radio 1 and 2
2
GE1/PoE
3
Console RJ45 connector
4
Reset button
5
Optional 12V DC power supply connector
6
BLE Radio
7
Kensington Lock Slot
8
2.4G/5G Radio 1 and 2
1
USB Port
Power Source
Description
Power over
Ethernet
(PoE)
Power is provided through the RJ45 Ethernet port (GE1 port)
to the right of the 12V DC port. This is the preferred method
of powering the AP on ceiling and high wall installations.
Figure 2 shows the LEDs on the front of the AP7632.
Figure 2 LEDs on AP Front Face
Green LEDs indicate 2G Wi-Fi Radio, Amber LEDs indicate 5.2G Wi-Fi Radio,
and Blue LED indicates the IoT Radio. The Status LED is Green only during
boot up and remains off during normal use.
For detailed installation information about the AP7632, see the Extreme
Networks WiNG AP7632 Installation Guide.
Verifying the AP7632 Box Contents
Verify the contents of the box and ensure that the following items are
available:
Mounting and Connecting the AP
Use these instructions as guidelines for mounting and connecting the AP7632
easily and safely.
The AP7632 comes with a Mounting Bracket (ordering part #37201) that can
be used to mount the AP on a flat surface. You can also purchase an optional
flat metal indoor bracket (ordering part #37210) for easy installation.
You also have an option to purchase the optional adapter if you want to mount
the AP on a suspended or drop ceiling.
For more information about installing the optional bracket and the adaptor,
see the Extreme Networks WiNG AP7632 Installation Guide.
For installation videos of the AP, see www.extremenetworks.com/support/
Mounting the AP on a Dry or Wood Wall/Solid Flat
Ceiling
To install the AP on a dry wall or flat surface:
Option 1: Using the Main Bracket
1 Use the main bracket as a template and mark the hole centers on the wall.
2 Drill two holes 81mm (3.200”) apart from each other on the wall where you
want to mount the AP.
3 Insert the screws through the bracket and into the holes. Use the screw-in
anchors if needed.
4 Insert the Ethernet cable’s RJ45 connector into the LAN1/GE1 port.
5 Slide the AP onto the bracket’s four feet. Ensure that the AP is secured in
place and tightened.
External 12V
DC power
supply
(optional)
The AP7632 can also be powered by an external DC power
supply plugged into an AC source. Plug the supply’s input
jack into the DC-In port (callout 5 in Figure 1).
1
IoT Radio
4
Status
2
Radio 2, 5GHz
3
Radio 1, 2.4GHz
Table 2 Contents of the AP7632 Box
Quantity Item
1 AP7632 Quick Reference Guide
1 Mounting Bracket for 802.11ac Indoor AP assembled onto the AP
1 Cloud Quick Start Card
The following hardware is included:
2 Phillips Pan-head wood screws
2 Screw-in anchors
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Note: Remove the main bracket from the AP to use it as a template.
Note: The four feet of the bracket must be horizontal and pointing to
the right. The flat part of the large surface must be touching the wall.
Power Source
Description
Option 2: Mounting the AP directly to the wall using 2 screws
1 Remove the main bracket attached to the back of the AP.
2 Drill two holes 104mm (4.100”) apart from each other on the wall.
3 Insert the screws into the holes and use the screw-in anchors if needed.
4 Insert the Ethernet cable’s RJ45 connector into the GE1 port (Figure 1; side
view). Attach the optional DC adaptor if there is no PoE on the Ethernet
cable.
5 Insert the keyholes of the AP onto the screws and slide it down till it is
firmly held by the screw heads. If the AP is loose, unmount the AP and
decrease the distance between the screw head and the wall. Remount the
AP.
Figure 3 Attaching AP to a Wall using 2 screws
Option 3: Using an optional Flat Metal Indoor Bracket
1 Attach the Flat Metal Indoor bracket to the main bracket. Keep the adaptor
to the center of the bracket, push and rotate it (Figure 4).
2 Hold the AP to the surface to which it needs to be attached and use the
optional adapter’s end holes as a template to mark the attachment holes.
3 Drill two holes on the solid surface (wall or ceiling) where you want to
mount the AP.
4 Connect the LAN/Ethernet cable to the back of the AP.
5 Hold the AP, insert and tighten the 2 screws until you lock it into place.
Figure 4 Attaching the optional Flat Metal Indoor Bracket to
the main bracket
Option 4: Using an optional Wall and Box bracket
Remove the main bracket from the AP. Follow the procedure mentioned in
ExtremeWireless AP7632 Installation Guide to mount the AP on a Wall and
Box bracket.
Mounting the AP to a Bracket on a Junction or Gang
Box
To mount the AP to a Bracket on a Junction or Gang box, use the Wall and Box
Bracket (needs to be purchased separately).
1 Remove the main bracket from the AP.
2 Follow the procedure mentioned in ExtremeWireless AP7632 Installation
Guide to mount the AP on a Wall and Box bracket.
Mounting the AP to a Suspended or Drop Ceiling
1 Attach the T-bar adaptor by pushing down the main bracket’s angled
locking tabs, pulling up on the T-bar adaptor’s locking pin, and
Note: Leave 1/8” gap between the screw head and the wall.
Note: Mounting the AP to a flat ceiling/wall requires the optional Flat
Metal Indoor Bracket (Purchasing Part #37210), which must be
purchased separately.
Note: Mounting the AP to a flat ceiling/wall requires either the Main
Bracket (Option 1), Flat Metal Indoor Bracket (Option 3), or the
optional Wall and Box Bracket (Option 4 - purchasing part #30516),
which must be purchased separately.
Note: The slot and lock cuts in the rear of the AP (visible when the
main plate is removed) are used for mounting the Wall and Box
bracket. The unlock tab on the bracket should be pointed up. In this
position, the AP7632 can be mounted with the antennas facing
upward or downward.
Note: Mounting the AP to a suspended or drop ceiling requires the
optional adapter (Universal Mounting Kit for EWLAN APs; purchasing
part # KT-135628-01), which must be purchased separately.
simultaneously rotating the adaptor onto the Main Bracket until the locking
pin clicks in place.
2 Slide the T-bar holder onto the T-bar and replace the tiles to hold the
adaptor onto the T-bar.
3 Hold the AP and rock it back and forth to ensure that it is securely
mounted.
4 Attach the Ethernet cable’s RJ45 connector to the LAN1/GE1 port.
The optional WS-MBI-DCMTR01 (purchasing part #30518) adaptor can also be
used for T-bar installations without the mounting bracket. For detailed
instructions, refer ExtremeWireless AP7632 Installation Guide.
Connecting a Power Supply to the AP7632
If you need to power the AP7632 with an external 12V DC power supply, you
can plug the power cord into the power connector (callout 5 in Figure 1) on the
back of the AP. There is no wall mount for the 12V DC power supply. When the
device is powered on, the power LED on the front face of the AP is lit. Refer to
the Extreme Networks WiNG AP7632 Installation Guide for
information about optional power supplies.
LAN/Console Connections
The AP7632 has one GE1 (Ethernet) port and a Console port. Refer to Figure 1
for the location of these ports. During administration and maintenance
through the GE1 or Console, the AP must still have a power connection
through either an Ethernet PoE cable or a DC power supply.
Professional Installation Instruction
Installation personal
This product is designed for specific application and needs to be installed by a
qualified personal who has RF and related rule knowledge. The general user
shall not attempt to install or change the setting.
Installation location
The product shall be installed at a location where the radiating antenna can be
kept 36 cm from nearby person in normal operation condition to meet
regulatory RF exposure requirement.
External antenna
Use only the antennas which have been approved by the applicant. The non-
approved antenna(s) may produce unwanted spurious or excessive RF
transmitting power which may lead to the violation of FCC/IC limit and is
prohibited.
Installation procedure
Please refer to user’s manual for the detail.
Instructions d'installation professionnelle
Installation
Ce produit est destine a un usage specifique et doit etre installe par un
personnel qualifie maitrisant les radiofrequences et les regles s'y rapportant.
L'installation et les reglages ne doivent pas etre modifies par l'utilisateur final.
Emplacement d'installation
En usage normal, afin de respecter les exigences reglementaires concernant
l'exposition aux radiofrequences, ce produit doit etre installe de facon a
respecter une distance de 36 cm entre l'antenne emettrice et les personnes.
Antenn externe
Utiliser uniiquement les antennes approuvees par le fabricant. L'utilisation
d'autres antennes peut conduire a un niveau de rayonnement essentiel ou non
essentiel depassant les niveaux limites definis par FCC/IC, ce qui est interdit.
Procedure d'installation
Consulter le manuel d'utilisation.
Warning: Please carefully select the installation position and make sure that
the final output power does not exceed the limit set force in relevant rules. The
violation of the rule could lead to serious federal penalty.
Warning: Avertissement: Choisir avec soin la position d'installation et
s'assurer que la puissance de sortie ne depasse pas les limites en vigueur. La
violation de cette regle peut conduire a de serieuses penalites federales.

Summary of content (2 pages)