Installation Guide

Table Of Contents
To replace a VIM, SSD, or clock module:
1. Attach an ESD-preventive wrist strap to your wrist and connect the metal end to an appropriate
ground point on the rack.
2. Disconnect the switch power.
3. Remove the existing VIM, SSD, or clock module:
a. Remove the retaining screws holding the existing module in place.
b. Save the retaining screws to secure the new module in the switch.
c. Pull the old module out of the module slot.
4. Remove the new VIM, SSD, or clock module from its anti-static packaging.
5. Install the VIM, SSD, or clock module in the switch:
a. Carefully slide the module into the switch.
b. Insert and tighten the retaining screws you removed in step 3. The clock module uses Phillips
screws and the VIM and SSD modules use slotted screws.
1
Soli d ON=Li nk
Blin king= Activ ity
S1 S2
Su mmit X46 0-G2 VIM-2x
TM
1 0GbE S FP +
Figure 445: Tighten Screws on the Inserted VIM5 Module
Figure 446: Tighten Screws on the Inserted SSD Module
1
11 PP
PP
SS
11
00 MM
HH
zz
OO
UU
TT
PP
UU
TT
TTMM--CCLLKK
Figure 447: Tighten Screws on the Inserted Clock Module
1= retaining screw locations
Replacing a Versatile Interface Module, Solid-state Drive,
or Clock Module in an X460-G2 Series or X465 Series
Switch Removing and Replacing Expansion Modules
510 Summit Family Hardware Installation Guide