- Extron Electronics Dual Link DVI Transmitter and Receiver User Manual
DVI DL 201 Tx/Rx • Installation
Installation, cont’d
2-14
Twisted pair output/input
Terminating shielded cable
CAT 5/5e/6/7 twisted pair cable is not provided with the 
transmitter/receiver pair. You may purchase cables that have 
been precut to the required length and terminated to the T586A 
or T586B standard (see the table on the next page).
Alternatively, purchase bulk cable and use the RJ-45 connectors 
(provided) to prepare your own terminated cables as described 
below.
N
  The transmitter and receiver pair works with unshielded 
twisted pair (UTP) or shielded twisted pair (STP) cables.  
To ensure FCC Class A and CE compliance, and for 
optimum performance, STP cables are recommended.
N
  Do not use Extron Skew Free Cable with this product.
1.  Cut the cables to the required length. All three cables 
should be the same length.
2.  Remove about 7/8" (2.2 cm) of the outer coat. If using STP 
cable, peel back the shielding and fold it over the top of the 
outer coat.
Peel back shield and
fold back.
3.  Cut away and discard the clear cellophane inner wrapper 
that extends beyond the folded back shielding.
4.  Cut a piece of self-adhesive shielded aluminum tape 
(provided), remove the backing, and wrap it around the 
folded back shielding.
Aluminum Tape
Wrap tape around folded foil shielding.
Slightly overlap.
Cut and save the excess tape
for other connectors.
5.  Separate the individual wires, and arrange them so that all 
eight wires are side by side in the same order as the T586A 
or T586B standard shown at the top of the next page. Both 
ends of a cable must be wired to the same standard (T586A 
or T586B).