DVI DL 201 Tx/Rx • Conguration and Operation
Configuration and Operation
Configuration
Using the EDID Minder to read and store EDID 
from a display
During boot up, the DVI-D source device uses Display Data 
Channel (DDC) to obtain Extended Display Identication Data 
(EDID) from the display device. This allows the output signal to 
match the resolution and refresh rate of the display device.
The DVI DL 201 Tx/Rx uses Extron's EDID Minder, which 
allows the user to store and use EDID from any display device. 
To use this feature, follow these steps:
1.  Disconnect all devices and cables from the transmitter and 
receiver.
2.  Connect the desired display to the transmitter's Local 
Monitor output. For best results, the cable for this 
connection should be 15' (4.5 m) or shorter.
3.  Apply power to the transmitter and the display device. If 
necessary, connect the power supply to the transmitter.
4.  Set the EDID Minder switch on the transmitter 
to the on (up) position (see the gure at right).
5.  Set the Default EDID switch to the off (down) 
position (see the gure at right).
6.  Set the Remote DDC to the off (down) 
position to allow DDC routing to go to the 
local monitor (see the gure at right).
N
  The EDID Minder extracts information only from the 
local monitor, not from the remote display.
7.  Press and release the EDID Minder Store 
button. The LED next to the switch turns 
from green to amber. This indicates that 
the transmitter is reading and extracting 
the EDID from the display connected to 
the local monitor output.
  When the information has been successfully extracted and 
stored in non-volatile memory, the LED returns to green.
8.  Turn off the display and disconnect it from the transmitter.
9.  Connect the transmitter to the receiver with the three 
twisted pair cables.
Transmitter port 1 connects to receiver port 1.• 
Transmitter port 2 connects to receiver port 2.• 
Transmitter port 3 connects to receiver port 3.• 
ON
1 2 3  
ON
OFF
DEFAULT EDID
EDID MINDER
REMOTE DDC
STORE
EDID