User's Manual

Cable Cubby 300/600/800 • Maintenance and Modifications 13
Extron
Cable Cubby 800
Pins
Phillips Head Screw
(Secures AAP Shelf Assembly
and Power Module.)
Screw Clamp
Figure 11. Removing the Cubby and its Shelves
4. Lift the enclosure from the table.
CAUTION: Risk of personal injury. The flanged edges of the top of the surface
enclosure are sharp. Exercise caution when the cubby is not installed in a table to
prevent personal injury.
ATTENTION: Potential Damage to Property. The flanged edges of the top
of the cubby are bevelled to an ultra-fine thickness of less than 0.04 inch (4/100
inch; approximately 1 mm). These edges are soft and can be easily nicked or bent.
Exercise caution when handling and mounting the enclosure. Mishandling can
damage the appearance of the enclosure.
5. Remove the AAP shelf assembly(ies) or power module by removing the four Phillips
head screws on the front and rear of the Cable Cubby and gently pushing the
assembly(ies) out through the top or bottom of the cubby.
6. Perform the desired maintenance procedure.
7. Reinstall the AAP shelf assembly(ies).
8. Carefully lower the Cable Cubby into the hole in the table.
9. From the underside of the table, reinstall the screw clamps on the enclosure at a height
at which the clamp will reach the underside of the tabletop.