User's Manual

Command/response table for SIS commands
Command ASCII (Telnet) URL Encoded (Web) Response
Relay Functions
Pulse Relay
X!
*3*
X6#
O
X!
%2A 3%2A
X6#
O Cpn
X!
•Rly
X%]
Toggle Relay
X!
*2O
X!
%2A 2O Cpn
X!
•Rly
X%]
Turn relay ON
X!
*1O
X!
%2A 1O Cpn
X!
•Rly1
]
Turn relay OFF
X!
*0O
X!
%2A0O Cpn
X!
•Rly0
]
View relay status
X!
O
X!
O
X%]
Input Contact Closure Port
View the input state or value
X!
]
X!
%5 D
X4#]
Firmware Version/Part Number/Information
Query firmware version Q Q
X1!]
Query verbose version
information
0Q 0Q
sum of responses from 2Q-3Q-4Q
]
Query firmware version 1Q 1Q
X1!]
Query bootstrap version 2Q 2Q
X1!]
Query factory firmware version 3Q 3Q
X1!
(plus web ver.-desc-UL date/time)
]
Query updated firmware version 4Q 4Q
X1!
(plus web ver.-desc-UL date/time)
]
NOTE: An asterisk (*) placed after the version number indicates which version is currently running. A question mark (?) indicates that only the factory firmware version is
loaded. A caret (^) after the version number indicates the firmware version that should be running, but a Mode 1 reset was executed. The default factory firmware
version is loaded. An exclamation point (!) after the version number indicates corrupted firmware.
Request part number N N
60-544-x5
]
Request model number 1I 1I
IPL T CR48
]
Request model description 2I 2I
Four contact input ports, Eight relay ports
]
Request system memory usage 3I 3I
# Bytes/Kbytes used out of # Kbytes
]
Request user memory usage 4I 4I
# Bytes/Kbytes used out of # Kbytes
]
NOTE:
X!
= Specific port number (01-99)
X%
= On/off status: 0 = off/disable; 1 = on/enable
X1!
= Unit firmware version
X4#
= 0 = off; 1 = on; value = 4095, based on a 12-bit A to D
X6#
= Pulse time in 20 milliseconds per count
IPL T CR48 • Communication and Control 28