User's Manual

6. If passwords were set up for the connected system, you will be prompted to log in as
Administrator or User. Otherwise, the system responds with a <cr/lf>.
7. Once you are connected, you can enter serial (ASCII) commands as desired.
8. When you are through entering commands to the IPL T CR48, type quit at the
command prompt to quit Telnet.
Troubleshooting
For best results, make connections in the following order. Turn on:
1. Control devices (such as a PC or laptop)
2. IPL T CR48
3. Output devices (such as projector lifts, screen lifts, and lighting systems)
If the output A/V device cannot be remotely controlled, check the following:
Power Connections
1. Ensure that all devices are plugged in.
2. Ensure that each device is receiving power. The power LED on the front panel of the
IPL T CR48 lights if the device is receiving power.
Data Connections
1. Check the cabling connections and make adjustments as needed. The LINK LEDs on the
IPL T CR48 and the computer should be solid green if a network connection is detected.
If these LEDs are not lit, either the cable is faulty or not plugged in, or the wrong
type of cable is being used (see Connecting the Hardware in the “Connection and
Configuration” section).
2. Try to ping the unit by typing ping 192.168.254.254 at the Windows command
prompt, or use the Web address provided to you by your system administrator. If you get
no response:
a. Ensure that your unit is using the appropriate subnet mask (check with your system
administrator).
b. Ensure that your PC does not have a software firewall program that might block the
IP address of the unit.
3. If contact is established with the unit but the unit Web pages cannot be accessed by
your Web browser, verify (in the Options or Preferences menu of the browser) that your
Web browser is configured for direct network connection and not set up to use a proxy
server.
If you are still experiencing problems, call the Extron S3 Sales & Technical Support Hotline.
Configuration
If, when configuring a unit, the MAC address on the rear panel is not visibly accessible and
the IP address is not known, use the direct PC connection method (see the Connection and
Configuration section).
NOTE: If the unit is not new (for example, out of the box), please see Resetting the
Controller in the “Installation and Operation” section for instructions on how to
reset the IP back to factory default.