User’s Manual RCP 2000 with ISS 506 Support Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Dubai +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没 有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与 厂家推荐的相同
Quick Start Guide — RCP 2000 with ISS 506 Support Step 1 Turn the equipment off and disconnect it from the power source. Make sure that the ISS 506 and all attached devices are turned off and, if applicable, disconnected from the power source. Step 2 Set the RCP 2000 on a table, podium, or other flat surface. Step 3 If using an RS-232 connection, connect the provided RS-232 cable to the RS-232 port on the rear panel of the ISS and to the To Switcher port on the rear panel of the RCP 2000.
Quick Start Guide — RCP 2000 with ISS 506 Support, cont’d Step 4 Complete the procedure for installing the ISS 506. (Refer to the ISS 506 User’s Manual for installation procedures.) Chapter One • Introduction ..................................................... 1-1 About this Manual ..................................................................... 1-2 About the RCP 2000 with ISS 506 Support ........................ 1-2 Features ........................................................................
Table of Contents, cont’d Sizing an image ..................................................................... 3-17 Resizing in PIP mode ............................................................3-17 Centering an image .............................................................. 3-17 Centering in PIP mode ..........................................................3-17 Adjusting the detail (sharpness) .......................................... 3-18 Resetting .........................................
Introduction About this Manual User preset recall — User presets save color, tint, contrast, brightness, detail, sizing, and centering settings on the ISS 506. Up to three presets can be saved on each input. You can recall a preset that was saved to an input button on the ISS by pressing the equivalent Preview input button on the RCP. Logos — The RCP can enable logos that have been created and assigned on the ISS 506 to be displayed on the output screen.
Introduction, cont’d RCP 2000 with ISS 506 Support 2 Chapter Two Installation Installation Overview Back Panel Features and Connections Making an RCP Communication Cable 1-4 RCP 2000 with ISS 506 Support • Introduction
Installation Installation Overview a Follow these steps to set up and install the RCP 2000 with ISS 506 support: 1 Turn all of the equipment off. Make sure that the ISS 506 and all attached devices are turned off and, if applicable, disconnected from the power source. 2 Set the RCP 2000 on a table, podium, or other flat surface.
Installation, cont’d Ethernet link • The RCP 2000 can also communicate with the ISS 506 via an Ethernet link, using the RJ-45 connectors on the RCP and the ISS. The RJ-45 connector is illustrated at right. The RCP 2000 can be connected to the ISS either directly, or indirectly through a LAN. • Pins: 12345678 RJ-45 Ethernet Patch Cable When connecting the RCP 2000 Side View directly (no intermediate device Insert present, such as a network hub) twisted to the ISS 506, you must use a pair wires.
Installation, cont’d RCP 2000 with ISS 506 Support 3 Chapter 3 Operation Top Panel Controls Setting Up IP Communication Setting Up RS-232 Communication Setting the Display Mode Using a Cut Transition Sub-effects Using the Picture Controls Resetting 2-6 RCP 2000 with ISS 506 Support • Installation
Operation Top Panel Controls The top panel contains the buttons, knobs, and the T-handle that are used to set up and control the RCP 2000 with the ISS 506. 1 LAMP Black — Causes a black screen to be displayed. You can switch the black screen by applying a cut or another effect. • 1 through 8 — Select the corresponding input (1–6) to be displayed. Normally, you do not use these buttons during a show. If a program input selection button is pressed, the resulting switch is not seamless.
Operation, cont’d e f g Transmit and Receive LEDs — These LEDs flicker whenever Ethernet or RS-232 data to or from the ISS 506 is being transmitted or received by the RCP 2000. i j Adjust knob — Allows adjustment of menu selections. See “Setting the Display Mode” or “Transition Sub-effects,” later in this chapter. k Transition effect buttons — Control the type of switch that occurs between program and preview inputs.
Operation, cont’d 3. Press and hold all four buttons.
Operation, cont’d 3. 4. Press Cut two times, until the switcher IP address is displayed in the LCD window. The Color/Tint button flashes. Power on 3 sec. Set the switcher’s IP address to 000.000.000.000 as follows: a. Press one of the picture control buttons to access the desired octet of the switcher’s IP address. b. When the desired octet is blinking in the LCD window, rotate the H knob all the way to the left to set the address block to 000. c.
Operation, cont’d To enter wipe mode, To enter title mode, 1. Press and hold the Wipe button. 1. Press and hold the Wipe button. 2. While holding down the Wipe button, repeatedly press the Dissolve button until “Wipe” is displayed on the LCD screen (see the example at right). 2. While holding down the Wipe button, repeatedly press the Dissolve button until “Title” is displayed on the LCD screen (see the example at right). 3. If necessary, select a preview input. 3. 4.
Operation, cont’d 3. If necessary, select a preview input. 4. To execute a switch with the dissolve effect, press the Take button, which blinks while the transition is in progress. Wipe and PIP Sub-effects 01 = Dissolve (PIP only) 10 = Soft Square In -orSlide the T-bar up or down to control the dissolve duration manually. Using a Cut A cut transition immediately and seamlessly replaces the program image with the preview image, in wipe or dissolve mode. In PIP mode, it closes or opens the PIP window.
Operation, cont’d • In from the top and bottom edges to the center of the screen — Soft Center In (#06) or Hard Center In (#18) • Out from the center to the top and bottom edges of the screen — Soft Center Out (#07) or Hard Center Out (#19) Dissolve (PIP mode only) A Dissolve sub-effect (#01 on the Sub-effects label) is available for switching the PIP window only. (To use a dissolve effect for a full-screen switch, see “Dissolve mode,” earlier in this chapter.
Operation, cont’d 4. Release the Wipe button and, while the button remains lit, rotate the Adjust knob to set the amount of seconds that the sub-effect will appear on the screen. You can set the duration of the PIP sub-effect in increments of tenths of a second, 0.0 to 0.5 seconds. Adjusting contrast and brightness 1. Press and release the Cont/Bright button. The button lights. 2. While the Cont/Bright button is lit, • Rotate the H Adjust knob to change the contrast.
Operation, cont’d 3. Rotate the H and V Adjust knobs to move the window or the image up and down (V knob) or left and right (H knob). The Center button stays lit steadily while you are centering the PIP window and blinks while you are centering the image. Adjusting the detail (sharpness) To apply a filter to improve the sharpness of an image, 1. Press and release the Detail button. The button lights. 2.
Ethernet Control The RCP 2000 Web pages allow you to control the RCP via Ethernet. They also enable the RCP to control a networked ISS 506 switcher. Establishing a Connection The resident Web pages are an alternative means of communication with, and control through, the RCP unit. The Web pages are accessed via a Web browser, such as Internet Explorer (version 5.5 or higher). The computer that is used to access the Web server must have a connection in common with the RCP unit.
Ethernet Control, cont’d Configuring the ISS 506 switcher In addition to RCP network configuration, passwords, and similar tasks, the Web pages can be used to control the ISS 506. To control the switcher via the Web pages, 1. Select the Configuration tab. 2. If the System Settings screen is not displayed, click System Settings on the sidebar menu. The System Settings screen opens. 3.
Ethernet Control, cont’d Updating the firmware Also available on the Configuration tab is the Firmware Upgrade screen. This screen lets you check and, if necessary, update the firmware for the RCP unit. N From the Configuration tab, click Firmware Upgrade in the menu column on the left side of the screen. The Firmware Upgrade screen appears, displaying the current firmware version (outlined in red in the illustration below).
Ethernet Control, cont’d Other file management activities You can also perform the following tasks on the File Management screen: Opening a file — Click on the name of the file in the Files column. Deleting a file — Click the Delete button at the right end of the line that contains the file you want to remove. Deleting all files — Click the Delete All button.
Ethernet Control, cont’d RCP 2000 with ISS 506 Support A Appendix A Specifications and Part Numbers Specifications Part Numbers 4-10 RCP 2000 with ISS 506 Support • Ethernet Control
Specifications and Part Numbers Specifications — RCP 2000 with ISS 506 Support Control/Remote — Control Panel Serial control port ������������������������� Baud rate and protocol ��������������� Serial control pin configurations � Ethernet control port �������������������� Ethernet data rate �������������������������� RS-232, 9-pin female D connector 9600, 8-bit, 1 stop bit, no parity 2 = TX, 3 = RX, 5 = GND 1 RJ-45 female connector 10/100Base-T, half/full duplex with autodetect Ethernet protocol �������
Specifications and Part Numbers, cont’d A-4 RCP 2000 with ISS 506 Support • Specifications and Part Numbers