User’s Manual DA RGB/YUV Series RGB and Component Video Distribution Amplifiers www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Quick Start Guide — DA RGB/YUV Step 1 Turn the equipment off and disconnect the equipment from the power source. Step 2 Rack, under-desk, or through-desk mount the DA as desired. DA2 RGBHV — Use an optional RSU 129 1U Rack Shelf, part #60-190-01, for rack mounting. Use an optional MBU 125 Under-Desk Mount Kit, part #70-077-01, to mount the DA under furniture. Use an optional MBD 129 Thru-Desk Mount Kit, part #70-077-02, to mount the DA through furniture.
Quick Start Guide — DA RGB/YUV, cont’d Chapter 1 • Introduction .......................................................... 1-1 Step 5 Video outputs — Connect RGB or component video displays or other devices as shown. You can use a DA6 YUV A to buffer RGsB or RsGsBs video. You can also output RGBS video by connecting the composite sync (S) plane on the digital audio BNC to the composite sync (S) input of the video displays or other devices.
Table of Contents, cont’d DA RGB/YUV Distribution Amplifiers 1 Chapter One Introduction About the Distribution Amplifiers ii DA RGB/YUV Distribution Amplifiers • Table of Contents
Introduction About the Distribution Amplifiers The Extron DA RGB/YUV series (figure 1-1) is a family of three RGB video distribution amplifiers (DAs) and one component video DA with digital audio. The DAs buffer one RGB or component video input and distribute the buffered signals to multiple destinations with no loss of signal quality.
Installation and Operation Installation Overview Install a DA RGB/YUV by performing the following steps: 1 Turn off the input and output devices, and unplug their power cords. 2 If desired, mount the DA in a rack, under a furniture surface, or through furniture. See Mounting Options, below. 3 Connect the input and all desired outputs. See Rear Panel Connections later in this chapter. 4 Plug in the DA and the input and output devices. Turn on the input and output devices.
Installation and Operation, cont’d Rack mounting the DA4 and DA6 1. Attach the rack mount brackets to the DA with the eight provided #8 machine screws (figure 2-2). Mounting Screws (2 Plcs) Each Side Drill pilot holes 3/32” (2.4 mm) diam 1/4” (6.
Installation and Operation, cont’d Through-furniture mounting the DA Slide the DA up and down or back and forth in the mounting brackets until the face of the DA is at the desired height. Tighten the screws that secure the bracket in place. 5. The DAs can be mounted through a desk or other furniture. The DA2 RGBHV requires an optional MBD 129 Through-Desk Mount Kit, part #70-077-02. The DA4 and DA6 models require the included through-desk and rack mounting bracket.
Installation and Operation, cont’d 1 7 100-240V 1.
Installation and Operation, cont’d 4 Digital audio output (DA6 YUV A only) — Connect digital audio devices to these female BNC connectors for each audio output. Controls and Indicators Each of the DAs has power LEDs on both the front panels (figure 2-11) and rear panels (figure 2-5 through figure 2-7) and two DIP switch controls on the rear panel. If you are using the DA to buffer RGBS video, connect this connector to the composite sync (S) input of the video displays or other devices.
Installation and Operation, cont’d Operation and Troubleshooting Connect the power cords and turn on the displays (projectors or monitors), the DA, and the input device (computer). The image should appear on the screens. DA RGB/YUV Distribution Amplifiers If the image does not appear or is not displayed correctly 1. Ensure that all devices are plugged in. 2. Make sure that each device is receiving power. The DA’s front and rear panel power LEDs indicate if the DA is receiving power. 3.
Reference Information Specifications Video Gain ............................................... 0 dB (unity), or 1.1 dB (110%), switchselectable (When input = 0.7 V, output = 0.7 V or 0.8 V, respectively.) Peaking .......................................... 0 dB or +6 dB at 100 MHz, switchselectable Bandwidth .................................... 350 MHz (-3 dB), fully loaded Video input Number/signal type DA6 YUV A ......................
Reference Information Digital audio — DA6 YUV A only Digital audio input/output is available when RGBS is not used as the video input signal. Sampling rates .............................. 32 kHz, 44.1 kHz, 48 kHz, 96 kHz, etcetera Digital audio input — DA6 YUV A only Number/signal type ................... Connectors .................................... Impedance .................................... Nominal level ...............................
Reference Information, cont’d Part Numbers Plenum Mini High Resolution Cable MHR-5P Plenum bulk, 500' (1000') DA part numbers M59 Cable Distribution Amplifier Part # M59-5 (-6) bulk, 500' DA2 RGBHV 60-488-01 Assorted connectors DA4 RGBHV 60-489-01 BNC connectors DA6 RGBHV 60-490-01 DA6 YUV A 60-494-01 Included parts Extron Part Part # Rack mounting bracket kit (DA4/6 models only) Part # RSU 129 1U Universal Rack Shelf Kit (DA2 RGBHV only) 60-190-01 MBU 125 Under-Desk Mount Kit (DA2 RGB
Reference Information, cont’d A-8 DA RGB/YUV Distribution Amplifiers • Reference Information