Setup Guide User Manual
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
Receive (Rx)
Transmit (Tx)
Ground ( )
Bidirectional
RS-232
Device
Ground ( )
Receive (Rx)
Transmit (Tx)
RxTx
Do not tin
the wires!
Disconnect Power and Mount the DMP64
Disconnect power to the DMP64 and turn off all devices connected to it. The DMP64 is housed in a half rack width, 9.5 inches
deep, 1U high metal enclosure that can sit on a table with the provided rubber feet or can be rack mounted. Select a suitable
mounting location, then choose an appropriate mounting option.
Connections
a Connect the Power Supply — The included power supply is prewired.
Plug the captive screw connector into the DMP64 power jack.
b Mic/Line Inputs — Attach up to six microphone or mono line level
devices, balanced or unbalanced, to the DMP64 using the audio input
wiring diagram shown at right.
c Connect the Audio Outputs — For balanced or unbalanced mono audio
output, connect an audio output device to each of the four outputs. Wire
the connectors as shown in the audio output wiring diagram shown at
right.
d Connect the I/O Ports — To control or monitor external devices, connect
up to six digital I/O ports (connections not shown). See the DMP64 User
Guide for additional information.
RESET
DMP 64
POWER
12V
1.0A MAX
LAN
123
456
4
5
6
1
2
3
4
Tx Rx G
RS-232 (2)
Tx Rx G
RS-232 (1)
456 G
123 G
MIC
+48V
1
3
2
MIC/LINE INPUTS
OUTPUTS
I/O
REMOTE
This guide provides basic instructions for an experienced technician
to install the DMP64 ProDSP
™
Digital Matrix Processor and
DSPCongurator
™
software. For additional information see the
DMP64 User Guide found at www.extron.com.
IP Address: 192.168.254.254
Subnet Mask: 255.255.0.0
Default Gateway: 0.0.0.0
DHCP: OFF
DMP 64 • Setup Guide
ATTENTION:
• For unbalanced audio outputs, connect
the sleeves to ground.
• DO NOT connect the sleeves to the
negative (–) contacts.
e Connect a Control System — There are three options to connect a
control system: LAN, RS‑232, and USB. Extron recommends using the
LAN port for conguration and remote control of the DMP64.
LAN — Using a standard Ethernet cable, connect to a network via the LAN port (
â
). The
table at right shows the default network settings.
NOTE: To connect the DMP64 directly to a computer, use a crossover Ethernet
cable.
RS-232 — Connect the host RS‑232 cable to the rear panel of the switcher (
à
) using the
provided 3‑pole captive screw connector (see the wiring diagram at right).
USB — Connect the host USB port to the front panel conguration port, (notshown), using
a USB A to mini‑B cable. The USB connection should be used only for conguration. Use
the RS‑232 or LAN port for remote control of the DMP64.
When all connections have been made, power up the input and output devices, then apply
power to the DMP64.
"
(5 mm) MAX. (typ)
3
16
Audio OUTPUT Wiring
Unbalanced Output
Tip
Sleeve
NO Ground Here
Balanced Output
Tip
Sleev
e
Ring
Audio INPUT Wiring
Balanced Input
Sleeve
Ring
Tip
Tip
Sleeve
Jumper
Unbalanced Input