User guide

DTP DVI 330 Tx/Rx Transmitter and Receiver • Installation and Operation 7
Supported cables —
The DTP DVI 330 is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP,
SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cable.
Cable recommendations —
Extron recommends using the following practices to achieve full transmission distances up
to 330 feet (100 m) and reduce transmission errors.
• Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the
best performance:
• XTP DTP 24/1000 Non‑Plenum 1000’ (305 m) spool 22‑236‑03
• XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22‑235‑03
• XTP DTP 24 Plug Package of 10 101‑005‑02
• If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
• Terminate cables with shielded connectors to the TIA/EIA T 568 B standard.
• Use no more than two pass‑through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass‑through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using CAT5e and CAT6 cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or Velcro
®
.
Separate twisted pair cables from AC power cables.