User Guide User Manual

Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Audio mutes
Mute audio
X@
*1Z Amt
X@
*1
]
Mute output
X@
audio (audio off).
Unmute audio
X@
*0Z Amt
X@
*0
]
Unmute output
X@
audio (audio on).
View audio mute status
X@
Z
X#]
Global audio mute
1*Z
Amt1
]
Mute all audio outputs.
Global audio unmute
0*Z
Amt0
]
Unmute all audio outputs.
Save, recall, and directly write global and room presets
NOTES:
If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
If the room is nonexistent, the matrix switcher responds with the error code E21.
The following characters are invalid or not recommended in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current configuration as a
global preset
X(
,
Spr
X(]
Command character is a comma.
Example:
9,
Spr09
]
Save current ties as preset 9.
Recall a global preset
X(
. Rpr
X(]
Command character is a period.
Example:
5.
Rpr05
]
Recall preset 5, which becomes the
current configuration.
Write room outputs
EX1)
,
X@
1
,
X@
2
, ...
X@
n
MR
}
Mpr
X1)
,
X@
1
,
X@
2
, ...
X@
n
]
See notes.
NOTES:
A room can contain a maximum of 16 outputs.
An output can belong to only one room.
The maximum number of rooms (
X1)
) is 10.
If no room name is assigned, the default name (
X1!
) is “
Room
#
X1)
••••”.
Example:
E
8,3,04,5,6MR
}
Mpr8,03,04,05,06
]
Outputs 3, 4, 5, and 6 are assigned to
room 8.
Read room outputs
EX1)
MR
}
X1!
,
X@
1
,
X@
2
, ...
X@
n
]
Example:
E
3MR
}
Room
#03
••••,
01
,
02
,
08
,
09
]
Outputs 1, 2, 8, and 9 are assigned to
room 3, which is named “Room #03”.
Save current configuration as a
room preset
X1)
*
X(
,
Rmm
X1)
Spr
X(
]
Command character is a comma.
Example:
3*9,
Rmm03Spr09
]
Save current ties as preset 9 for room 3.
Recall room preset
X1)
*
X(
.
Rmm
X1)
Rpr
X(]
Command character is a period.
NOTE: X@ = Output number 01 – (maximum number of outputs for your model)
X# = Mute status 0 = off (unmuted) 1 = on (muted)
X( = Global or room preset number 00 - 32, 10 maximum for a room preset (00 = current configuration for view only)
X1) = Room number (for room presets) 10 max. (Each can have up to 10 presets (X(s) assigned.)
X1! = Name 12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.
CrossPoint and MAV Series Matrix Switchers • Programming Guide 98