User Guide User guide

Control/remote — external device (pass-through, unidirectional or bidirectional)
Serial control ports
Input/output
............................ 1 set of proprietary signals on a female RJ-45 jack
Output/input ........................... RS-232 via (1) 3.5 mm, 3 pole captive screw connector
Baud rates ...................................... Up to 38400 bps at up to 1000' (300 m)
Protocol ......................................... Data bits = 5 - 8
Stop bits = 1 or 2
Parity = odd, even, none
Flow control = XON, XOFF, none
NOTE: Protocol is mirrored between the transmitter and the receiver.
Serial control pin configuration ....... Captive screw connectors: 1 = Tx, 2 = Rx, 3 = GND
General
Recommended cable type .............. CAT 5/5e/6 (shielded or unshielded)
Power supply .................................. External
Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 1 A, 12 watts
Power input requirements
.............. 12 VDC, 1.0 A max.
Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling .......................................... Convection, vents sides to top
Mounting
Rack mount ............................. Yes, with optional 1U rack shelf
Wall mount .............................. Yes, with optional wall mounting kit
Enclosure type ................................ Metal
Enclosure dimensions ..................... 1.0" H x 8.75" W x 6.0" D (half rack wide)
(2.5 cm H x 22.2 cm W x 15.2 cm D)
(Depth excludes connectors.)
Product weight ............................... 1 lb (0.5 kg)
Shipping weight ............................. 2 lbs (1 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ...................................... CE, c-UL, UL
EMI/EMC ................................. CE, C-tick, FCC Class A, ICES, VCCI
MTBF ............................................. 30,000 hours
Warranty ........................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
MTP 1500RL 15HD RS SEQ • Reference Information 12