Mounting
This section outlines the various mounting options available for the MTP 1500RL RS unit:
z Tabletop Placement
z Rack Mounting
z Under-desk Mounting
z Through-desk Mounting
Tabletop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in any
convenient location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation
of these products in a rack:
1. Elevated operating ambient temperature If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F,
+50 °C) specied by Extron.
2. Reduced air flow Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
3. Mechanical loading Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
4. Circuit overloading Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of the equipment nameplate ratings should be used when
addressing this concern.
5. Reliable earthing (grounding) Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as the use of power strips).
MTP 1500RL 15HD RS SEQ • Mounting 14